37
OPERATION
PROCEDURE
THREAD BREAK SENSORSets the thread break detection sensing level.
1 Change the display to FUNCTION MENU.
2 Select "2. THRED SNS" (thread break detection sensor).
3 Select the desired setting.
Setting: OFF / 1 / 2 / 3 / 4 / 5
- OFF: Does not detect break of
thread.
- 1 - 5: Detects break of thread at
the set number of
stitches.
∗ Sensitivity gets higher when a
smaller number is set.
4 Press [SET] to confirm the setting.
5 End of operation
FD07
Press .
***** EMB START ****
AISIN123.10O 1
0/ 1027
01/15: 23456789AB<D>
1
*** FUNCTION MENU **
1DISPLAY ST
2.THRED SNS OFF
3.BOBBIN CNT [SET]
.Move the cursor using (hoop
travel key).
Select "OFF", "1", "2", "3", "4" or "5"
for "THRED SENS" using the follow-
ing keys:
and (hoop travel keys)
*** FUNCTION MENU **
1.DISPLAY ST
2 THRED SNS OFF
3.BOBBIN CNT [SET]
.
*** FUNCTION MENU **
1.DISPLAY ST
2 THRED SNS 3
3.BOBBIN CNT [SET]
.Press .
***** EMB START ****
AISIN123.10O 1
0/ 1027
01/15: 23456789AB<D>
1