L2 Managed Switch
CCCCCCCCCCCLightning Protection
3333 Cabling Reasonably
In the actual network environment, you may need cable outdoors and indoors, and the requirements for cabling outdoors and indoors are different. A reasonable cabling system can decrease the damage of induced lightning to devices.
Note: It’s not recommended using Ethernet cables outdoors. When cabling outdoors, please use a signal lightning arrester.
■■ Requirements for Cabling Outdoors
■■ Aerial cabling without safeguard is not allowed.
■■ It’s not allowed cabling down the building to connect network devices in different floors.
■■ Outdoor cables should be buried and paved to the indoor through basement. A piece of steel wire should be paved underground along the pipe and connected to the lightning protection terminal of the building for shielding. Before connecting the cable to the device, install a signal lightning arrester on the corresponding port.
■■ When an aerial cable is set up, the cable should be through a metal pipe (15m long at least\ before coming into the building. The two ends of this metal pipe should be grounded. Before connecting the cable to the device, install a signal lightning arrester on the corresponding port.
■■ It’s not necessary to pave STP cables through pipes. The shielded layer of STP cable should be well grounded. Before connecting the cable to the device, install a signal lightning arrester on the corresponding port.
■■ Requirements for Cabling Indoors
When cabling indoors, keep a certain distance away from the devices that may cause
■■ The main cable should be paved in the metal raceway of the access shaft. When cabling, keep the loop area formed by the cable itself as small as possible.
10 Lightning Protection