L2 Managed Switch

Requirements for the distance between Ethernet cable and other pipelines are shown in the table.

 

 

Ethernet Cable

Other Pipelines

 

 

 

Min Parallel Net Length

 

Min Parallel-overlapping Net Height

 

L (mm1

 

H (mm1

 

 

 

 

Down-conductor

1000

 

300

 

 

 

 

PE

50

 

20

 

 

 

 

Service pipe

150

 

20

 

 

 

 

Compressed air pipe

150

 

20

 

 

 

 

Thermal pipe (not wrapped1

500

 

500

 

 

 

 

Thermal pipe (wrapped1

300

 

300

 

 

 

 

Gas pipe

300

 

20

 

 

 

 

The two diagrams below demonstrate parallel net length and parallel-overlapping net height.

Note: The above minimum net length/height is required when metal raceway is not used. If any requirements cannot be met, you can add a steel tube or metal raceway for shielding.

Requirements for the distance between Ethernet cable and high-power electric devices are in following tables.

Cable

 

Pave Way

 

 

Min Parallel

 

 

 

Length (mm1

 

 

 

 

 

 

 

 

 

 

 

<2kVA

 

Parallel cabling

130

 

 

 

 

 

 

One is in the grounded metal raceway or metal pipe

70

powerline

 

 

 

 

 

 

 

The both are in the grounded metal raceway or metal pipe

10

 

 

 

 

 

 

 

 

2~5kVA

 

Parallel cabling

300

 

 

 

 

 

 

One is in the grounded metal raceway or metal pipe

150

powerline

 

 

 

 

 

 

 

The both are in the grounded metal raceway or metal pipe

80

 

 

 

 

 

 

 

 

>5kVA

 

Parallel cabling

600

 

 

 

 

 

 

One is in the grounded metal raceway or metal pipe

300

powerline

 

 

 

 

 

 

 

The both are in the grounded metal raceway or metal pipe

150

 

 

 

 

 

 

 

 

 

 

 

 

 

Device

 

Min Distance (m1

 

 

 

 

 

 

 

Switch case

 

1.00

 

 

 

 

 

 

Transformer room

2.00

 

 

 

 

 

 

Elevator tower

2.00

 

 

 

 

 

 

Air-conditioner room

2.00

 

 

 

 

 

 

 

 

Lightning Protection 11

Page 15
Image 15