*UD2B080A9V3VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
| AIRFLOW | DIP SWITCH SETTING |
|
| EXTERNAL STATIC PRESSURE |
| ||||
| SETTING |
|
|
|
|
|
|
|
| |
| SW 7 | SW 8 |
| 0.1 | 0.3 | 0.5 | 0.7 | 0.9 | ||
|
|
| ||||||||
|
|
|
| CFM | 800 | 790 | 765 | 750 | 730 | |
| LOW | ON | ON | TEMP. RISE | 48 | 49 | 50 | 52 | 53 | |
|
|
|
| WATTS | 100 | 135 | 155 | 200 | 230 | |
|
|
|
|
|
|
|
|
|
| |
HEATING |
|
|
| CFM | 910 | 890 | 875 | 860 | 820 | |
1ST | MEDIUM ** | ON | OFF | TEMP. RISE | 43 | 44 | 44 | 45 | 47 | |
STAGE |
|
|
| WATTS | 130 | 170 | 210 | 240 | 280 | |
|
|
|
|
|
|
|
|
|
| |
|
|
|
| CFM | 1060 | 1020 | 1010 | 1010 | 1000 | |
| HIGH | OFF | OFF | TEMP. RISE | 37 | 38 | 39 | 39 | 39 | |
|
|
|
| WATTS | 188 | 220 | 265 | 310 | 350 | |
|
|
|
|
|
|
|
|
|
| |
|
|
|
| CFM | 1110 | 1090 | 1090 | 1080 | 1065 | |
| LOW | ON | ON | TEMP. RISE | 54 | 55 | 55 | 55 | 56 | |
|
|
|
| WATTS | 210 | 260 | 310 | 350 | 400 | |
|
|
|
|
|
|
|
|
|
| |
HEATING | MEDIUM ** |
|
| CFM | 1245 | 1240 | 1240 | 1230 | 1215 | |
2ND | ON | OFF | TEMP. RISE | 48 | 48 | 48 | 48 | 49 | ||
| ||||||||||
STAGE |
|
|
| WATTS | 300 | 355 | 410 | 460 | 500 | |
|
|
|
|
|
|
|
|
|
| |
|
|
|
| CFM | 1415 | 1400 | 1400 | 1375 | 1320 | |
| HIGH | OFF | OFF | TEMP. RISE | 42 | 42 | 42 | 43 | 45 | |
|
|
|
| WATTS | 410 | 470 | 530 | 580 | 590 | |
|
|
|
|
|
|
|
|
|
|
*UD2B080A9V3VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR | AIRFLOW |
| DIP SWITCH SETTING |
|
|
| EXTERNAL STATIC PRESSURE |
| |||||||
UNIT SIZE |
|
|
|
|
| ||||||||||
SETTING |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
(TONS) | SW 1 |
| SW 2 | SW 3 |
| SW 4 |
| 0.1 |
| 0.3 | 0.5 | 0.7 |
| 0.9 | |
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LOW | OFF |
| ON | OFF |
| ON | CFM | 880 |
| 875 | 860 | 845 |
| 840 |
| (350 CFM/TON) |
|
| WATTS | 120 |
| 155 | 190 | 225 |
| 245 | ||||
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2.5 | NORMAL | OFF |
| ON | OFF |
| OFF | CFM | 1020 |
| 1000 | 990 | 980 |
| 960 |
(400 CFM/TON) |
|
| WATTS | 170 |
| 205 | 240 | 280 |
| 320 | |||||
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HIGH | OFF |
| ON | ON |
| OFF | CFM | 1110 |
| 110 | 1110 | 1100 |
| 1100 |
| (450 CFM/TON) |
|
| WATTS | 210 |
| 260 | 320 | 350 |
| 385 | ||||
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LOW | ON |
| OFF | OFF |
| ON | CFM | 1040 |
| 1010 | 1000 | 1000 |
| 990 |
| (350 CFM/TON) |
|
| WATTS | 190 |
| 220 | 260 | 310 |
| 340 | ||||
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3.0 | NORMAL | ON |
| OFF | OFF |
| OFF | CFM | 1200 |
| 1200 | 1190 | 1190 |
| 1175 |
(400 CFM/TON) |
|
| WATTS | 250 |
| 320 | 370 | 415 |
| 450 | |||||
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HIGH | ON |
| OFF | ON |
| OFF | CFM | 1340 |
| 1340 | 1330 | 1320 |
| 1300 |
| (450 CFM/TON) |
|
| WATTS | 355 |
| 425 | 475 | 530 |
| 570 | ||||
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LOW | OFF |
| OFF | OFF |
| ON | CFM | 1215 |
| 1210 | 1210 | 1200 |
| 1185 |
| (350 CFM/TON) |
|
| WATTS | 265 |
| 330 | 375 | 430 |
| 465 | ||||
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3.5 ** | NORMAL ** | OFF |
| OFF | OFF |
| OFF | CFM | 1430 |
| 1415 | 1410 | 1385 |
| 1330 |
(400 CFM/TON) |
|
| WATTS | 415 |
| 457 | 520 | 575 |
| 580 | |||||
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HIGH | OFF |
| OFF | ON |
| OFF | CFM | 1430 |
| 1415 | 1410 | 1385 |
| 1330 |
| (450 CFM/TON) |
|
| WATTS | 415 |
| 475 | 520 | 575 |
| 580 | ||||
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTES:
1.* First Letter may be "A" or "T"
2.** Factory setting
3.Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value.
4.LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting
10 | DATA SUBJECT TO CHANGE WITHOUT NOTICE |
|