Trane TUD2D120B9V5VB, TUD2D140A9V5VB, TUD2D120A9V5VB, TUD2C100B9V5VB manual 22-1650-13, Airflow

Models: TUD2C080B9V4VB TUD2D120B9V5VB TUD2C100A9V5VB TUD2C080A9V4VB TUD2B080A9V3VB TUD2B100A9V3VB TUD2C100B9V5VB TUD2D120A9V5VB TUD2D140A9V5VB

1 26
Download 26 pages 53.7 Kb
Page 16
Image 16
Manual background

*UD2D120A9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

 

AIRFLOW

 

DIP SWITCH SETTING

 

 

 

 

 

 

EXTERNAL STATIC PRESSURE

 

 

SETTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW7

 

SW8

 

 

 

0.1

0.3

 

0.5

 

0.7

 

 

0.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1007

1062

 

1084

 

1063

 

 

1063

 

LOW

 

 

ON

 

ON

TEMP. RISE

57

54

 

53

 

54

 

 

54

 

 

 

 

 

 

 

 

WATTS

114

177

 

285

 

303

 

 

350

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING

 

 

 

 

 

 

 

 

CFM

1154

1211

 

1211

 

1221

 

 

1212

1ST

MEDIUM **

 

 

ON

 

OFF

TEMP. RISE

50

48

 

48

 

47

 

 

48

STAGE

 

 

 

 

 

 

 

WATTS

167

230

 

277

 

344

 

 

417

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1288

1319

 

1310

 

1349

 

 

1358

 

HIGH

 

 

OFF

 

OFF

TEMP. RISE

45

44

 

44

 

43

 

 

43

 

 

 

 

 

 

 

 

WATTS

208

273

 

330

 

410

 

 

460

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1387

1421

 

1455

 

1488

 

 

1495

 

LOW

 

 

ON

 

ON

TEMP. RISE

64

63

 

61

 

60

 

 

59

 

 

 

 

 

 

 

 

WATTS

250

320

 

400

 

460

 

 

540

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING

 

 

 

 

 

 

 

 

CFM

1589

1637

 

1666

 

1678

 

 

1541

2ND

MEDIUM **

 

 

ON

 

OFF

TEMP. RISE

56

54

 

53

 

53

 

 

58

STAGE

 

 

 

 

 

 

 

WATTS

350

440

 

535

 

600

 

 

575

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1771

1788

 

1804

 

1751

 

 

1554

 

HIGH

 

 

OFF

 

OFF

TEMP. RISE

50

50

 

49

 

51

 

 

57

 

 

 

 

 

 

 

 

WATTS

475

560

 

650

 

675

 

 

590

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*UD2D120A9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR

AIRFLOW

 

 

DIP SWITCH SETTING

 

 

 

 

EXTERNAL STATIC PRESSURE

UNIT SIZE

SETTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(TONS)

(See Notes)

 

SW1

 

SW2

 

SW3

 

SW4

 

 

 

0.1

 

0.3

0.5

 

0.7

 

0.9

 

LOW

 

OFF

 

ON

 

OFF

 

ON

 

CFM

 

1195

 

1243

1235

 

1251

1251

 

(350 CFM/ TON)

 

 

 

 

 

WATTS

 

150

 

225

275

 

325

410

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.5

NORMAL

 

OFF

 

ON

 

OFF

 

OFF

 

CFM

 

1353

 

1403

1417

 

1437

1458

(400 CFM/ TON)

 

 

 

 

 

WATTS

 

210

 

290

370

 

425

485

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

 

OFF

 

ON

 

ON

 

OFF

 

CFM

 

1554

 

1572

1615

 

1634

1567

 

(450 CFM/ TON)

 

 

 

 

 

WATTS

 

315

 

410

480

 

570

575

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

 

ON

 

OFF

 

OFF

 

ON

 

CFM

 

1356

 

1391

1399

 

1433

1454

 

(350 CFM/ TON)

 

 

 

 

 

WATTS

 

200

 

280

370

 

420

510

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

NORMAL

 

ON

 

OFF

 

OFF

 

OFF

 

CFM

 

1565

 

1584

1633

 

1639

1554

(400 CFM/ TON)

 

 

 

 

 

WATTS

 

320

 

410

475

 

560

575

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

 

ON

 

OFF

 

ON

 

OFF

 

CFM

 

1766

 

1799

1810

 

1784

1590

 

(450 CFM/ TON)

 

 

 

 

 

WATTS

 

450

 

550

650

 

685

600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

 

OFF

 

OFF

 

OFF

 

ON

 

CFM

 

1708

 

1758

1759

 

1775

1575

 

(350 CFM/ TON)

 

 

 

 

 

WATTS

 

420

 

530

585

 

675

585

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 **

NORMAL **

 

OFF

 

OFF

 

OFF

 

OFF

 

CFM

 

1994

 

2018

1971

 

1814

1618

(400 CFM/ TON)

 

 

 

 

 

WATTS

 

665

 

775

785

 

725

625

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

 

OFF

 

OFF

 

ON

 

OFF

 

CFM

 

2247

 

2152

2019

 

1861

1693

 

(450 CFM/ TON)

 

 

 

 

 

WATTS

 

975

 

925

860

 

765

680

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES: "CONTINUOUS FAN SETTING" IS THERMOSTAT FAN SWITCH "ON" AND DIP SWITCHS 5 AND 6 "ON".

1.*FIRST LETTER MAY BE "A" OR "T"

2.**FACTORY SETTING.

3.CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE.

4.LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.

16

DATA SUBJECT TO CHANGE WITHOUT NOTICE

22-1650-13

Page 16
Image 16
Trane TUD2D120B9V5VB, TUD2D140A9V5VB, TUD2D120A9V5VB, TUD2C100B9V5VB, TUD2B100A9V3VB, TUD2B080A9V3VB manual 22-1650-13, Airflow