*UD2D120A9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
| AIRFLOW |
| DIP SWITCH SETTING |
|
|
|
|
|
| EXTERNAL STATIC PRESSURE |
| |||||||||||
| SETTING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| SW7 |
| SW8 |
|
|
| 0.1 | 0.3 |
| 0.5 |
| 0.7 |
|
| 0.9 | |||||
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| CFM | 1007 | 1062 |
| 1084 |
| 1063 |
|
| 1063 | ||||
| LOW |
|
| ON |
| ON | TEMP. RISE | 57 | 54 |
| 53 |
| 54 |
|
| 54 | ||||||
|
|
|
|
|
|
|
| WATTS | 114 | 177 |
| 285 |
| 303 |
|
| 350 | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HEATING |
|
|
|
|
|
|
|
| CFM | 1154 | 1211 |
| 1211 |
| 1221 |
|
| 1212 | ||||
1ST | MEDIUM ** |
|
| ON |
| OFF | TEMP. RISE | 50 | 48 |
| 48 |
| 47 |
|
| 48 | ||||||
STAGE |
|
|
|
|
|
|
| WATTS | 167 | 230 |
| 277 |
| 344 |
|
| 417 | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| CFM | 1288 | 1319 |
| 1310 |
| 1349 |
|
| 1358 | ||||
| HIGH |
|
| OFF |
| OFF | TEMP. RISE | 45 | 44 |
| 44 |
| 43 |
|
| 43 | ||||||
|
|
|
|
|
|
|
| WATTS | 208 | 273 |
| 330 |
| 410 |
|
| 460 | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| CFM | 1387 | 1421 |
| 1455 |
| 1488 |
|
| 1495 | ||||
| LOW |
|
| ON |
| ON | TEMP. RISE | 64 | 63 |
| 61 |
| 60 |
|
| 59 | ||||||
|
|
|
|
|
|
|
| WATTS | 250 | 320 |
| 400 |
| 460 |
|
| 540 | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HEATING |
|
|
|
|
|
|
|
| CFM | 1589 | 1637 |
| 1666 |
| 1678 |
|
| 1541 | ||||
2ND | MEDIUM ** |
|
| ON |
| OFF | TEMP. RISE | 56 | 54 |
| 53 |
| 53 |
|
| 58 | ||||||
STAGE |
|
|
|
|
|
|
| WATTS | 350 | 440 |
| 535 |
| 600 |
|
| 575 | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| CFM | 1771 | 1788 |
| 1804 |
| 1751 |
|
| 1554 | ||||
| HIGH |
|
| OFF |
| OFF | TEMP. RISE | 50 | 50 |
| 49 |
| 51 |
|
| 57 | ||||||
|
|
|
|
|
|
|
| WATTS | 475 | 560 |
| 650 |
| 675 |
|
| 590 | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
*UD2D120A9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER | ||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
OUTDOOR | AIRFLOW |
|
| DIP SWITCH SETTING |
|
|
|
| EXTERNAL STATIC PRESSURE | |||||||||||||
UNIT SIZE | SETTING |
|
|
|
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
(TONS) | (See Notes) |
| SW1 |
| SW2 |
| SW3 |
| SW4 |
|
|
| 0.1 |
| 0.3 | 0.5 |
| 0.7 |
| 0.9 | ||
| LOW |
| OFF |
| ON |
| OFF |
| ON |
| CFM |
| 1195 |
| 1243 | 1235 |
| 1251 | 1251 | |||
| (350 CFM/ TON) |
|
|
|
|
| WATTS |
| 150 |
| 225 | 275 |
| 325 | 410 | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
3.5 | NORMAL |
| OFF |
| ON |
| OFF |
| OFF |
| CFM |
| 1353 |
| 1403 | 1417 |
| 1437 | 1458 | |||
(400 CFM/ TON) |
|
|
|
|
| WATTS |
| 210 |
| 290 | 370 |
| 425 | 485 | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| HIGH |
| OFF |
| ON |
| ON |
| OFF |
| CFM |
| 1554 |
| 1572 | 1615 |
| 1634 | 1567 | |||
| (450 CFM/ TON) |
|
|
|
|
| WATTS |
| 315 |
| 410 | 480 |
| 570 | 575 | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| LOW |
| ON |
| OFF |
| OFF |
| ON |
| CFM |
| 1356 |
| 1391 | 1399 |
| 1433 | 1454 | |||
| (350 CFM/ TON) |
|
|
|
|
| WATTS |
| 200 |
| 280 | 370 |
| 420 | 510 | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
4 | NORMAL |
| ON |
| OFF |
| OFF |
| OFF |
| CFM |
| 1565 |
| 1584 | 1633 |
| 1639 | 1554 | |||
(400 CFM/ TON) |
|
|
|
|
| WATTS |
| 320 |
| 410 | 475 |
| 560 | 575 | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| HIGH |
| ON |
| OFF |
| ON |
| OFF |
| CFM |
| 1766 |
| 1799 | 1810 |
| 1784 | 1590 | |||
| (450 CFM/ TON) |
|
|
|
|
| WATTS |
| 450 |
| 550 | 650 |
| 685 | 600 | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| LOW |
| OFF |
| OFF |
| OFF |
| ON |
| CFM |
| 1708 |
| 1758 | 1759 |
| 1775 | 1575 | |||
| (350 CFM/ TON) |
|
|
|
|
| WATTS |
| 420 |
| 530 | 585 |
| 675 | 585 | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
5 ** | NORMAL ** |
| OFF |
| OFF |
| OFF |
| OFF |
| CFM |
| 1994 |
| 2018 | 1971 |
| 1814 | 1618 | |||
(400 CFM/ TON) |
|
|
|
|
| WATTS |
| 665 |
| 775 | 785 |
| 725 | 625 | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| HIGH |
| OFF |
| OFF |
| ON |
| OFF |
| CFM |
| 2247 |
| 2152 | 2019 |
| 1861 | 1693 | |||
| (450 CFM/ TON) |
|
|
|
|
| WATTS |
| 975 |
| 925 | 860 |
| 765 | 680 | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTES: "CONTINUOUS FAN SETTING" IS THERMOSTAT FAN SWITCH "ON" AND DIP SWITCHS 5 AND 6 "ON".
1.*FIRST LETTER MAY BE "A" OR "T"
2.**FACTORY SETTING.
3.CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE.
4.LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.
16 | DATA SUBJECT TO CHANGE WITHOUT NOTICE |