TUD-R9V PRODUCT SPECIFICATIONS1

MODEL

TUD2C100B9V5VB 5

TUD2D120A9V5VB

TUD2D120B9V5VB 5

TUD2D140A9V5VB

TYPE

 

Upflow / Horizontal

Upflow / Horizontal

Upflow / Horizontal

Upflow / Horizontal

RATINGS 2

 

 

 

 

 

1st Stage Input BTUH

 

65,000

78,000

78,000

91,000

  1st Stage Capacity BTUH (ICS) 3

 

52,000

62,400

62,400

72,800

2nd Stage Input BTUH

 

100,000

120,000

120,000

140,000

  2nd Stage Capacity BTUH (ICS) 3

79,000

97,000

97,000

111,000

Temp. rise (Min.-Max.) °F.

 

35 - 65

35 - 65

35 - 65

40 - 70

BLOWER DRIVE

 

Direct

Direct

Direct

Direct

Diameter - Width (In.)

 

10 x 10

10 x 10

10 x 10

10 x 10

No. Used

 

1

1

1

1

Speeds (No.)

 

Variable

Variable

Variable

Variable

CFM vs. in. w.g.

 

See Airflow Table

See Airflow Table

See Airflow Table

See Airflow Table

Motor HP

 

1

1

1

1

R.P.M.

 

Variable

Variable

Variable

Variable

Volts / Ph / Hz

 

115/1/60

115/1/60

115/1/60

115/1/60

COMBUSTION FAN - Type

 

Centrifugal

Centrifugal

Centrifugal

Centrifugal

Drive - No. Speeds

 

Direct - 2

Direct - 2

Direct - 2

Direct - 2

Motor HP - RPM

 

1/50 - 3000

1/50 - 3000

1/50 - 3000

1/50 - 3000

Volts / Ph / Hz

 

115/1/60

115/1/60

115/1/60

115/1/60

FLA

 

0.87

1.14

1.14

1.16

FILTER — Furnished?

 

Yes

Yes

Yes

Yes

Type Recommended

 

High Velocity

High Velocity

High Velocity

High Velocity

Hi Vel. (No.-Size-Thk.)

 

1 - 20x25 - 1in.

1 - 24x25 - 1in.

1 - 24x25 - 1in.

1 - 24x25 - 1in.

VENT — Size (In.)

 

4 Round

4 Round

4 Round

4 Round

HEAT EXCHANGER

 

 

 

 

 

Type -Fired

 

Alum. Steel - Type 1

Alum. Steel - Type 1

Alum. Steel - Type 1

Alum. Steel - Type 1

-Unfired

 

 

 

 

 

Gauge (Fired)

 

20

20

20

20

ORIFICES — Main

 

 

 

 

 

Nat. Gas. Qty. — Drill Size

 

5 — 45

6 — 45

6 — 45

7 — 45

L. P. Gas Qty. — Drill Size

 

5 — 56

6 — 56

6 — 56

7 — 56

GAS VALVE

Redundant - Two Stage

Redundant - Two Stage

Redundant - Two Stage

Redundant - Two Stage

PILOT SAFETY DEVICE

 

 

 

 

 

Type

 

Hot Surface Ignition

Hot Surface Ignition

Hot Surface Ignition

Hot Surface Ignition

BURNERS — Type

 

Multi-port In-shot

Multi-port In-shot

Multi-port In-shot

Multi-port In-shot

Number

 

5

6

6

7

POWER CONN. — V / Ph / Hz 4

 

115/1/60

115/1/60

115/1/60

115/1/60

Ampacity (In Amps)

 

14.9

15.3

15.3

15.3

Max. Overcurrent Protection (Amps)

 

20

20

20

20

PIPE CONN. SIZE (In.)

 

1/2

1/2

1/2

1/2

DIMENSIONS

 

H x W x D

H x W x D

H x W x D

H x W x D

Crated (In.)

 

41-3/4 x 23 x 30-1/2

41-3/4 x 26-1/2 x 30-1/2

41-3/4 x 26-1/2 x 30-1/2

41-3/4 x 26-1/2 x 30-1/2

WEIGHT

 

 

 

 

 

Shipping (Lbs.) / Net (Lbs.)

 

166 / 155

193 / 181

193 / 181

197 / 185

1Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3

2For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.

3Based on U.S. government standard tests.

4The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

5 Model uses high efficiency blower.