Trane TUD2C080A9V4VB, TUD2D140A9V5VB, TUD2D120A9V5VB, TUD2C100B9V5VB manual 22-1650-13, Airflow

Models: TUD2C080B9V4VB TUD2D120B9V5VB TUD2C100A9V5VB TUD2C080A9V4VB TUD2B080A9V3VB TUD2B100A9V3VB TUD2C100B9V5VB TUD2D120A9V5VB TUD2D140A9V5VB

1 26
Download 26 pages 53.7 Kb
Page 14
Image 14
Manual background

*UD2C100A9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

 

AIRFLOW

DIP SWITCH SETTING

 

 

EXTERNAL STATIC PRESSURE

 

 

SETTING

 

 

 

 

 

 

 

 

 

SW 7

SW 8

 

0.1

0.3

0.5

0.7

0.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

900

890

870

850

835

 

LOW

ON

ON

TEMP. RISE

53

54

55

57

58

 

 

 

 

WATTS

100

130

175

220

270

 

 

 

 

 

 

 

 

 

 

HEATING

 

 

 

CFM

1125

1090

1060

1070

1070

1ST

MEDIUM **

ON

OFF

TEMP. RISE

43

44

46

45

45

STAGE

 

 

 

WATTS

150

200

235

300

340

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1300

1300

1320

1350

1340

 

HIGH

OFF

OFF

TEMP. RISE

37

37

36

36

36

 

 

 

 

WATTS

220

290

365

430

490

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1270

1290

1290

1290

1280

 

LOW

ON

ON

TEMP. RISE

59

58

58

58

58

 

 

 

 

WATTS

200

260

335

400

460

HEATING

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1575

1600

1610

1600

1580

2ND

MEDIUM **

ON

OFF

TEMP. RISE

47

46

46

46

47

STAGE

 

 

 

WATTS

355

445

520

575

650

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1870

1890

1860

1870

1730

 

HIGH

OFF

OFF

TEMP. RISE

40

39

40

40

43

 

 

 

 

WATTS

560

665

710

830

760

 

 

 

 

 

 

 

 

 

 

*UD2C100A9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

OUTDOOR

AIRFLOW

 

DIP SWITCH SETTING

 

 

 

EXTERNAL STATIC PRESSURE

 

UNIT SIZE

 

 

 

 

 

SETTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(TONS)

SW 1

 

SW 2

SW 3

 

SW 4

 

0.1

 

0.3

0.5

0.7

 

0.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

ON

 

ON

OFF

 

ON

CFM

1075

 

1055

1015

1000

 

990

 

(350 CFM/TON)

 

 

WATTS

135

 

185

220

265

 

325

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.0

NORMAL

ON

 

ON

OFF

 

OFF

CFM

1220

 

1200

1210

1210

 

1210

(400 CFM/TON)

 

 

WATTS

185

 

240

295

350

 

410

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

ON

 

ON

ON

 

OFF

CFM

1390

 

1390

1410

1410

 

1400

 

(450 CFM/TON)

 

 

WATTS

245

 

320

391

470

 

510

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

OFF

 

ON

OFF

 

ON

CFM

1214

 

1210

1215

1210

 

1210

 

(350 CFM/TON)

 

 

WATTS

185

 

240

295

350

 

415

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.5

NORMAL

OFF

 

ON

OFF

 

OFF

CFM

1430

 

1460

1470

1460

 

1440

(400 CFM/TON)

 

 

WATTS

310

 

355

430

500

 

555

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

OFF

 

ON

ON

 

OFF

CFM

1640

 

1665

1650

1640

 

1610

 

(450 CFM/TON)

 

 

WATTS

370

 

460

540

615

 

660

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

ON

 

OFF

OFF

 

ON

CFM

1405

 

1430

1440

1440

 

1420

 

(350 CFM/TON)

 

 

WATTS

270

 

310

375

480

 

550

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.0

NORMAL

ON

 

OFF

OFF

 

OFF

CFM

1670

 

1675

1670

1655

 

1630

(400 CFM/TON)

 

 

WATTS

395

 

490

550

630

 

700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

ON

 

OFF

ON

 

OFF

CFM

1870

 

1880

1880

1845

 

1670

 

(450 CFM/TON)

 

 

WATTS

540

 

635

730

800

 

640

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

OFF

 

OFF

OFF

 

ON

CFM

1775

 

1800

1820

1800

 

1680

 

(350 CFM/TON)

 

 

WATTS

480

 

580

680

750

 

740

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.0 **

NORMAL **

OFF

 

OFF

OFF

 

OFF

CFM

2065

 

2020

1945

1805

 

1623

(400 CFM/TON)

 

 

WATTS

755

 

840

900

880

 

800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

OFF

 

OFF

ON

 

OFF

CFM

2310

 

2100

2100

1965

 

1800

 

(450 CFM/TON)

 

 

WATTS

1000

 

1000

950

890

 

825

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

1.* First letter may be "A" or "T"

2.** Factory setting

3.Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value.

4.LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting

14

DATA SUBJECT TO CHANGE WITHOUT NOTICE

22-1650-13

Page 14
Image 14
Trane TUD2C080A9V4VB, TUD2D140A9V5VB, TUD2D120A9V5VB, TUD2C100B9V5VB, TUD2B100A9V3VB, TUD2B080A9V3VB manual 22-1650-13, Airflow