Trane TUD2C100A9V5VB, TUD2D140A9V5VB, TUD2D120A9V5VB Eneral Data, TUD-R9VPRODUCT SPECIFICATIONS1

Models: TUD2C080B9V4VB TUD2D120B9V5VB TUD2C100A9V5VB TUD2C080A9V4VB TUD2B080A9V3VB TUD2B100A9V3VB TUD2C100B9V5VB TUD2D120A9V5VB TUD2D140A9V5VB

1 26
Download 26 pages 53.7 Kb
Page 6
Image 6

ENERAL DATA

TUD-R9V PRODUCT SPECIFICATIONS1

MODEL

TUD2B060A9V3VB

TUD2B080A9V3VB

TUD2C080A9V4VB

 

 

 

 

TYPE

Upflow / Horizontal

Upflow / Horizontal

Upflow / Horizontal

 

 

 

 

RATINGS 2

 

 

 

1st Stage Input BTUH

39,000

52,000

52,000

  1st Stage Capacity BTUH (ICS) 3

31,200

41,600

41,600

2nd Stage Input BTUH

60,000

80,000

80,000

  2nd Stage Capacity BTUH (ICS) 3

48,000

64,000

64,000

Temp. rise (Min.-Max.) °F.

30 - 60

30 - 60

30 - 60

 

 

 

 

BLOWER DRIVE

Direct

Direct

Direct

Diameter - Width (In.)

10 x 7

10 x 7

10 x 10

No. Used

1

1

1

Speeds (No.)

Variable

Variable

Variable

CFM vs. in. w.g.

See Airflow Table

See Airflow Table

See Airflow Table

Motor HP

1/2

1/2

3/4

R.P.M.

Variable

Variable

Variable

Volts / Ph / Hz

115/1/60

115/1/60

115/1/60

 

 

 

 

COMBUSTION FAN - Type

Centrifugal

Centrifugal

Centrifugal

Drive - No. Speeds

Direct - 2

Direct - 2

Direct - 2

Motor HP - RPM

1/50 - 3000

1/50 - 3000

1/50 - 3000

Volts / Ph / Hz

115/1/60

115/1/60

115/1/60

FLA

0.7

0.7

0.7

 

 

 

 

FILTER — Furnished?

Yes

Yes

Yes

Type Recommended

High Velocity

High Velocity

High Velocity

Hi Vel. (No.-Size-Thk.)

1 - 17x25 - 1in.

1 - 17x25 - 1in.

1 - 20x25 - 1in.

 

 

 

 

VENT — Size (In.)

4 Round

4 Round

4 Round

 

 

 

 

HEAT EXCHANGER

 

 

 

Type -Fired

Alum. Steel - Type 1

Alum. Steel - Type 1

Alum. Steel - Type 1

-Unfired

 

 

 

Gauge (Fired)

20

20

20

 

 

 

 

ORIFICES — Main

 

 

 

Nat. Gas. Qty. — Drill Size

3 — 45

4 — 45

4 — 45

L. P. Gas Qty. — Drill Size

3 — 56

4 — 56

4 — 56

 

 

 

 

GAS VALVE

Redundant - Two Stage

Redundant - Two Stage

Redundant - Two Stage

 

 

 

 

PILOT SAFETY DEVICE

 

 

 

Type

Hot Surface Ignition

Hot Surface Ignition

Hot Surface Ignition

 

 

 

 

BURNERS — Type

Multi-port In-shot

Multi-port In-shot

Multi-port In-shot

Number

3

4

4

 

 

 

 

POWER CONN. — V / Ph / Hz 4

115/1/60

115/1/60

115/1/60

Ampacity (In Amps)

10.5

10.5

12.9

Max. Overcurrent Protection (Amps)

15

15

20

 

 

 

 

PIPE CONN. SIZE (In.)

1/2

1/2

1/2

 

 

 

 

DIMENSIONS

H x W x D

H x W x D

H x W x D

Crated (In.)

41-3/4 x 19-1/2 x 30-1/2

41-3/4 x 19-1/2 x 30-1/2

41-3/4 x 23 x 30-1/2

 

 

 

 

WEIGHT

 

 

 

Shipping (Lbs.) / Net (Lbs.)

136 / 126

142 / 132

166 / 155

 

 

 

 

1Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3

2For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.

3Based on U.S. government standard tests.

4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

6

DATA SUBJECT TO CHANGE WITHOUT NOTICE

22-1650-13

Page 6
Image 6
Trane TUD2C100A9V5VB, TUD2D140A9V5VB, TUD2D120A9V5VB, TUD2C100B9V5VB manual Eneral Data, TUD-R9VPRODUCT SPECIFICATIONS1