Trane TUD2C080B9V4VB, TUD2D140A9V5VB, TUD2D120A9V5VB, TUD2C100B9V5VB manual Airflow, 22-1650-13

Models: TUD2C080B9V4VB TUD2D120B9V5VB TUD2C100A9V5VB TUD2C080A9V4VB TUD2B080A9V3VB TUD2B100A9V3VB TUD2C100B9V5VB TUD2D120A9V5VB TUD2D140A9V5VB

1 26
Download 26 pages 53.7 Kb
Page 17
Image 17
Manual background

*UD2D120B9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

 

AIRFLOW

 

DIP SWITCH SETTING

 

 

 

 

 

 

EXTERNAL STATIC PRESSURE

 

 

SETTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S4-3

 

S4-4

 

 

 

0.1

0.3

 

0.5

 

0.7

 

 

0.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1050

1044

 

1035

 

1005

 

 

980

 

LOW

 

 

ON

 

ON

TEMP. RISE

45

46

 

46

 

47

 

 

48

 

 

 

 

 

 

 

 

WATTS

99

146

 

208

 

252

 

 

310

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING

 

 

 

 

 

 

 

 

CFM

1214

1216

 

1217

 

1192

 

 

1169

1ST

MEDIUM **

 

 

ON

 

OFF

TEMP. RISE

39

39

 

39

 

40

 

 

41

STAGE

 

 

 

 

 

 

 

WATTS

129

188

 

262

 

252

 

 

310

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1288

1293

 

1298

 

1275

 

 

1254

 

HIGH

 

 

OFF

 

OFF

TEMP. RISE

37

37

 

37

 

37

 

 

38

 

 

 

 

 

 

 

 

WATTS

147

212

 

293

 

309

 

 

373

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1429

1440

 

1453

 

1435

 

 

1416

 

LOW

 

 

ON

 

ON

TEMP. RISE

48

48

 

47

 

48

 

 

48

 

 

 

 

 

 

 

 

WATTS

191

267

 

363

 

340

 

 

406

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING

 

 

 

 

 

 

 

 

CFM

1672

1695

 

1722

 

1711

 

 

1697

2ND

MEDIUM **

 

 

ON

 

OFF

TEMP. RISE

41

40

 

40

 

40

 

 

40

STAGE

 

 

 

 

 

 

 

WATTS

310

402

 

528

 

409

 

 

480

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1782

1809

 

1890

 

1835

 

 

1871

 

HIGH

 

 

OFF

 

OFF

TEMP. RISE

39

38

 

36

 

37

 

 

37

 

 

 

 

 

 

 

 

WATTS

385

480

 

623

 

565

 

 

644

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*UD2D120B9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

OUTDOOR

AIRFLOW

 

 

DIP SWITCH SETTING

 

 

 

 

EXTERNAL STATIC PRESSURE

UNIT SIZE

SETTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(TONS)

(See Notes)

 

S3-1

 

S3-2

 

S3-3

 

S3-4

 

 

 

0.1

 

0.3

0.5

 

0.7

 

0.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

 

OFF

 

ON

 

OFF

 

ON

 

CFM

 

1208

 

1209

1210

 

1185

1162

 

(350 CFM/ TON)

 

 

 

 

 

WATTS

 

128

 

186

260

 

306

370

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.5

NORMAL

 

OFF

 

ON

 

OFF

 

OFF

 

CFM

 

1343

 

1350

1358

 

1337

1317

(400 CFM/ TON)

 

 

 

 

 

WATTS

 

162

 

232

318

 

365

433

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

 

OFF

 

ON

 

ON

 

OFF

 

CFM

 

1477

 

1491

1507

 

1490

1472

 

(450 CFM/ TON)

 

 

 

 

 

WATTS

 

210

 

290

391

 

436

508

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

 

ON

 

OFF

 

OFF

 

ON

 

CFM

 

1343

 

1350

1358

 

1337

1317

 

(350 CFM/ TON)

 

 

 

 

 

WATTS

 

162

 

232

318

 

365

433

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.0

NORMAL

 

ON

 

OFF

 

OFF

 

OFF

 

CFM

 

1496

 

1511

1528

 

1511

1494

(400 CFM/ TON)

 

 

 

 

 

WATTS

 

218

 

300

403

 

447

520

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

 

ON

 

OFF

 

ON

 

OFF

 

CFM

 

1650

 

1671

1698

 

1686

1671

 

(450 CFM/ TON)

 

 

 

 

 

WATTS

 

296

 

387

511

 

548

626

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

 

OFF

 

OFF

 

OFF

 

ON

 

CFM

 

1612

 

1631

1655

 

1642

1627

 

(350 CFM/ TON)

 

 

 

 

 

WATTS

 

274

 

363

482

 

521

598

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.0 **

NORMAL **

 

OFF

 

OFF

 

OFF

 

OFF

 

CFM

 

1858

 

1902

1907

 

1906

1871

(400 CFM/ TON)

 

 

 

 

 

WATTS

 

403

 

533

624

 

714

755

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

 

OFF

 

OFF

 

ON

 

OFF

 

CFM

 

1871

 

2126

2110

 

2098

2001

 

(450 CFM/ TON)

 

 

 

 

 

WATTS

 

585

 

711

797

 

888

953

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES: "CONTINUOUS FAN SETTING" IS THERMOSTAT FAN SWITCH "ON" AND DIP SWITCHS 5 AND 6 "ON".

1.*FIRST LETTER MAY BE "A" OR "T"

2.**FACTORY SETTING.

3.CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE.

4.LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.

22-1650-13