Trane TUD2C100B9V5VB, TUD2D140A9V5VB, TUD2D120A9V5VB, TUD2B100A9V3VB manual General Features

Models: TUD2C080B9V4VB TUD2D120B9V5VB TUD2C100A9V5VB TUD2C080A9V4VB TUD2B080A9V3VB TUD2B100A9V3VB TUD2C100B9V5VB TUD2D120A9V5VB TUD2D140A9V5VB

1 26
Download 26 pages 53.7 Kb
Page 2
Image 2
General Features

General Features

NATURAL GAS MODELS

Central Heating furnace designs are cer- tified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standart rating condi- tions using American National Standards Instirute standards.

SAFE OPERATION

The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heaating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety.

QUICK HEATING

Durable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm condi- tioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside.

BURNERS

Multiport In-shot burners will give years of quiet and efficient service. All models can be converted to L.P. gas.

INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connection points for E.A.C./humidifier.

AIR DELIVERY

The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. Some models are available with high efficiency blowers.

STYLING

Heavy gauge steel and “wrap-around” cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient opera- tion due to the excellent acoustical and insulating qualities of fiberglass. Built-in bottom pan and alternate bottom, left or right side return air connection provision.

FEATURES AND GENERAL OPERA- TION

The XV80 High Efficiency Gas Furnaces employ a Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a de- mand for heat from the room thermostat. Complete front service access.

a.Low energy power venter

b.Vent proving pressure switch.

© 2011 Trane

2

22-1650-13

Page 2
Image 2
Trane TUD2C100B9V5VB, TUD2D140A9V5VB, TUD2D120A9V5VB, TUD2B100A9V3VB, TUD2B080A9V3VB, TUD2C080A9V4VB manual General Features