AIRFLOW

*UD2B060A9V3VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

 

AIRFLOW

DIP SWITCH SETTING

 

 

EXTERNAL STATIC PRESSURE

 

 

SETTING

 

 

 

 

 

 

 

 

 

SW7

SW8

 

0.1

0.3

0.5

0.7

0.9

 

 

 

 

 

 

 

CFM

589

604

619

604

607

 

LOW

ON

ON

TEMP. RISE

49

48

47

48

48

 

 

 

 

WATTS

65

95

125

160

200

 

 

 

 

 

 

 

 

 

 

HEATING

 

 

 

CFM

663

694

684

681

686

1ST

MEDIUM **

ON

OFF

TEMP. RISE

44

42

42

42

42

STAGE

 

 

 

WATTS

75

120

145

185

220

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

775

781

776

805

811

 

HIGH

OFF

OFF

TEMP. RISE

37

37

37

36

36

 

 

 

 

WATTS

105

145

180

230

270

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

813

818

818

837

842

 

LOW

ON

ON

TEMP. RISE

55

54

54

53

53

 

 

 

 

WATTS

110

150

185

240

280

 

 

 

 

 

 

 

 

 

 

HEATING

 

 

 

CFM

907

919

942

958

959

2ND

MEDIUM **

ON

OFF

TEMP. RISE

49

48

47

46

46

STAGE

 

 

 

WATTS

140

200

240

300

330

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1038

1066

1086

1089

1079

 

HIGH

OFF

OFF

TEMP. RISE

43

42

41

41

41

 

 

 

 

WATTS

190

260

325

365

415

 

 

 

 

 

 

 

 

 

 

*UD2B060A9V3VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

OUTDOOR

AIRFLOW

 

DIP SWITCH SETTING

 

 

 

EXTERNAL STATIC PRESSURE

 

UNIT SIZE

 

 

 

 

 

SETTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(TONS)

SW1

 

SW2

SW3

 

SW4

 

0.1

 

0.3

0.5

0.7

 

0.9

 

 

 

 

 

 

 

LOW

ON

 

ON

OFF

 

ON

CFM

499

 

537

520

520

 

500

 

(350 CFM/ TON)

 

 

WATTS

50

 

80

110

145

 

175

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.5

NORMAL

ON

 

ON

OFF

 

OFF

CFM

605

 

610

610

597

 

593

(400 CFM/ TON)

 

 

WATTS

60

 

80

120

155

 

180

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

ON

 

ON

ON

 

OFF

CFM

649

 

681

665

665

 

672

 

(450 CFM/ TON)

 

 

WATTS

75

 

110

145

180

 

220

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

OFF

 

ON

OFF

 

ON

CFM

680

 

722

680

696

 

696

 

(350 CFM/ TON)

 

 

WATTS

80

 

125

150

190

 

225

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

NORMAL

OFF

 

ON

OFF

 

OFF

CFM

798

 

804

809

823

 

818

(400 CFM/ TON)

 

 

WATTS

105

 

145

170

235

 

280

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

OFF

 

ON

ON

 

OFF

CFM

884

 

896

924

931

 

931

 

(450 CFM/ TON)

 

 

WATTS

145

 

180

240

280

 

330

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

ON

 

OFF

OFF

 

ON

CFM

858

 

863

882

894

 

895

 

(350 CFM/ TON)

 

 

WATTS

125

 

175

220

275

 

320

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.5

NORMAL

ON

 

OFF

OFF

 

OFF

CFM

984

 

1017

1038

1017

 

1017

(400 CFM/ TON)

 

 

WATTS

170

 

225

295

330

 

375

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

ON

 

OFF

ON

 

OFF

CFM

1125

 

1138

1150

1161

 

1161

 

(450 CFM/ TON)

 

 

WATTS

245

 

315

370

435

 

475

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

OFF

 

OFF

OFF

 

ON

CFM

1035

 

1056

1076

1076

 

1076

 

(350 CFM/ TON)

 

 

WATTS

205

 

265

330

370

 

430

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 **

NORMAL **

OFF

 

OFF

OFF

 

OFF

CFM

1208

 

1247

1268

1278

 

1200

(400 CFM/ TON)

 

 

WATTS

300

 

360

440

485

 

490

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

OFF

 

OFF

ON

 

OFF

CFM

1380

 

1410

1402

1350

 

1235

 

(450 CFM/ TON)

 

 

WATTS

440

 

500

550

550

 

525

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

1.*FIRST LETTER MAY BE "A" OR "T"

2.**FACTORY SETTING.

3.CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE.

4.LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.

22-1650-13