S4TEF10xx-10x

Installation -- Continued

Switch Set #1 - T1/E1 Options

5, 6, 7, 8 - Loop-Back Settings

The loop-back setting is used for installation and network debugging procedures. Each of the T1/E1 ports can be individually set for loop-back mode:

• Switch 5 controls T1/E1 port 1

• Switch 6 controls T1/E1 port 2

• Switch 7 controls T1/E1 port 3

• Switch 8 controls T1/E1 port 4

When the loop-back switch for a particular T1/E1 port is enabled, the port loops the signal from the receive port back to the transmit port. The loop-back test scenarios are described in detail on page 16.

5

6

up

up

Disable Loop-Back on T1/E1 port 1

Disable Loop-Back on T1/E1 port 2

down

down

 

Enable Loop-Back on T1/E1 port 1

Enable Loop Back on T1/E1 port 2

7

8

Installation -- Continued

Switch Set #2 - Serial Options

1, 2, 3 - Serial Connection Speed Line Settings

Switches 1, 2, and 3 on switch set #2 are used to set the serial connection speed.

1

2

3

1

2

3

1200 baud

19200 baud

2400 baud

38400 baud

4800 baud

57600 baud

9600 baud

115200 baud

up

up

Disable Loop-Back on T1/E1 port 3

Disable Loop-Back on T1/E1 port 4

down

down

Enable Loop-Back on T1/E1 port 3

Enable Loop-Back on T1/E1 port 4

4. Enable / Disable Parity

When parity is enabled, an additional bit is added to the 8-bit signal to identify whether the signal is sent successfully. Use switch 5 to send odd or even signal parity.

up - Disable parity.

down - Enable parity.

4

up

Disable Parity

down

Enable Parity

9 - Transmit AIS

up - Enables the transmit AIS (Alarm Indication Signal) on loss of the carrier signal. This function is un-framed and applies to ALL channels, both copper and fiber.

down - Disables the transmit AIS function.

9

up

Enable

down

Disable

 

5

5. Parity Select

up

up - Select odd serial parity.

Odd Serial Parity

down - Select even serial parity.

down

 

This switch is inactive if switch 4 is (up).

Even Serial Parity

 

10 - RS-232 Port Mode

up - Data port mode (normal operation). Transmits data to a desk top computer or other data collection device

down - Local (auxiliary) management mode. See the SNMP section (page 11) for the commands that are supported via the RS-232 connector.

10

up

Data port mode

down

Local management mode

4