Transition Networks MIL-SM2401MAF
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
104
Cables
The RJ-45 ports on the switch support automatic MDI/MDI-X operation, so you can use
standard straight-through twisted-pair cables to connect to any other network device
(PCs, servers, switches, routers, or hubs). P lease refer to the following table for cable
specifications.
Cable Types and Specifications
Cable Type Max. Length Connector
10BASE-T Cat. 3, 4, 5 100-ohm UTP /STP 100 m
(328 ft) RJ-45
100BASE-TX Cat. 5 100-ohm UTP/STP 100 m
(328 ft) RJ-45
1000BASE-T Cat. 5e, 6 100-ohm UTP/STP 100 m
(328 ft) RJ-45
Cable specification table
100BASE-TX/10BASE-T Pin Assignments
With 100BASE-TX/10BASE-T cable, pins 1 and 2 are used for transmitting data, and
pins 3 and 6 for receiving data.
RJ-45 Pin Assignments
Pin Number Assignment
1 Tx+
2 Tx-
3 Rx+
6 Rx-
Note: “+” and “-” signs represent the polarity of the wires that make up each wire pair.