Transition Networks MIL-SM2401MAF Use the 802.1x misc, quiet period global, Switch config#, mode

Models: MIL-SM2401MAF

1 178
Download 178 pages 19.96 Kb
Page 58
Image 58

 

 

Use the 802.1x misc

 

 

 

 

quiet period global

 

Switch (config)#

8021x misc

 

configuration command

 

8021x misc

quietperiod

Global

to specify the quiet

 

quietperiod 10

[sec.]

period value of the

 

 

configuration

60 sec.

 

Or

switch.

(Default)

mode

 

no 8021x misc

 

 

Switch(config)#

 

 

 

quietperiod

 

Use the no form of this

 

no 8021x misc

 

 

command to return to

 

quietperiod

 

 

the default interval.

 

 

 

 

 

 

 

 

 

Use the 802.1x misc TX

 

Switch (config)#

8021x misc

 

period global

 

8021x misc

 

configuration command

 

txperiod 5

txperiod [sec.]

Global

 

to set the TX period.

 

 

Or

configuration

30 sec.

 

 

(Default)

no 8021x

mode

 

 

Use the no form of this

 

Switch(config)# no

txperiod

 

 

 

command to return to

 

8021x misc

 

 

 

 

 

the default value.

 

txperiod

 

 

 

 

 

8021x misc

Global

Set the period of time

 

Switch (config)#

the switch wait for a

 

supptimeout

configuration

30 sec.

8021x misc

supplicant response to

[sec.]

mode

 

supptimeout 30

an EAP request.

 

 

 

 

 

 

 

 

 

 

8021x misc

Global

Set the period of time

 

Switch (config)#

the switch wait for a

 

servertimeout

configuration

30 sec.

8021x misc

server response to an

[sec.]

mode

 

servertimeout 50

authentication request.

 

 

 

 

 

 

 

 

 

 

8021x misc

Global

Set the number of

 

Switch (config)#

maxrequest

configuration

authentication that must

2

8021x misc

[Number]

mode

time-out before

 

maxrequest 2

 

 

 

 

 

 

 

50

 

 