V. CARE & MAINTENANCE (cont’d)
V. d - CLEANING THE EXTERIOR:
Exterior stainless steel should be cleaned with warm water, mild soap and a soft cloth. Apply with a damp- ened cloth and wipe in the direction of the metal grain.
Avoid the use of strong detergents and gritty, abra- sive cleaners as they may tend to mar and scratch the surface. Do NOT use cleansers containing chlorine, this may promote corrosion of the stainless steel.
Care should also be taken to avoid splashing the unit with water, containing chlorinated cleansers, when mopping the floor around the unit.
For stubborn odor spills, use baking soda and water (mixed to a 1 TBSP baking soda to 1 pint water ratio).
V. e - CLEANING THE INTERIOR:
For cleaning both stainless steel and anodized alumi- num interiors, the use of baking soda as described in section “V. d” is recommended. Use on breaker strips as well as door gaskets. All interior fittings are remov- able without tools to facilitate cleaning.
VI. MISC. OPERATIONS
VI. a - ADJUSTING THE SHELVES:
For shelves mounted on pins, first select the desired location and remove the white plastic covers in the interior back and sides by rotating them
°F°C
SET
FREEZER
VII. MICROPROCESSOR CONTROL
Your new Traulsen R or A Series Convertible Refrigerator or Freezer is equipped with an electronic microprocessor control, which precisely regulates opera- tion. It is supplied from the factory completely ready for use. See pages 5 thru 14 for more information.
VIII. a - MICROPROCESSOR CONTROL FEATURES:
Internal Time Clock
•Eliminates defrost time clock (refrigerator and freezer models only).
•Will display only at “Start Up”.
•Must be reset after a power failure.
•See “Setting The
•Will automatically update for Daylight Savings Time. See “Setting Daylight Savings Time” on page 11.
Water Resistant Housing
The digital controller is water resistant not only from the face of the control, but also from the rear of the housing.
Parameter/Service Levels
•See “Customer/Service Parameters” on Page 7 - 8.
Defrost Lockouts - See “Setting Defrost Lockouts” on page 13
•Customers can set up to 4 different defrost lockout periods. The lockout prevents the unit from going into a defrost cycle during peak kitchen use. Note: The