VII. INTELA-TRAUL®

VII. INTELA-TRAUL®

Your new Traulsen Undercounter Refrigerator or Freezer is equipped with a state-of-the-art electronic microproces- sor INTELA-TRAUL®control, which precisely regulates operation and provides alarms when problems occur. It is supplied from the factory completely ready for use but without the audible alarms activated. See pages 8 thru 17 for more information.

VII. a - INTELA-TRAUL®CONTROL FEATURES:

Internal Time Clock

Eliminates defrost time clock.

Will display only at Start Up.

Must be reset after a power failure.

See Setting The 24-Hour Clockon Page 12 (Also required at Start Up).

Will automatically update for Daylight Savings Time. See Setting Daylight Savings Timeon page 13.

Water Resistant Housing

The INTELA-TRAUL®control is water resistant not only from the face of the control, but also from the rear of the housing.

Parameter/Service Levels

See Customer / Service Parameterson Page 9.

Defrost Lockouts - See Setting Defrost Lockoutson page 15.

Customers can set up to 4 different defrost lockout periods. The lockout prevents the unit from going into a defrost cycle during peak kitchen use. Note: The 24-hour clock must be set for this feature to operate correctly.

Data Storage

The control comes equipped with 72 hours worth of data storage capability including:

Records cabinet air temperatures every 6 minutes, needed to document Due Diligencein accordance with HAACP standards.

Records alarm events.

Records diagnostic test of each sensor every 24 hours.

Records failed security attempts.

Records door open cycles.

Records defrost cycles (refrigerator and freezer models only).

Note: The 24-hour clock and the date must be set for the above information to be recorded at the correct time and date.

Communication Ability

An RS485 port is available as a means of retrieving information from the stored data.

Smart Recovery

In the event that a sensor fails, the INTELA-TRAUL®control will maintain the same compressor operation & defrost cycles that it recorded over the previous 72 hours in order to maintain the operation of the unit until service arrives.

Alarms (See the following pages for explanations)

High Cabinet Air Temperature

Low Cabinet Air Temperature

Loss Of Power

CONDENSERCLEAN*

Sensor Failures

*Not Available On Remote Models