Tripp Lite G1010USB owner manual Basic Operation Rear Panel

Models: G1010USB

1 20
Download 20 pages 35.73 Kb
Page 5
Image 5

Basic Operation (Front Panel) continued

“FAULT” Icon: This icon will illuminate and an alarm will sound after a self-test to indicate the battery-supported outlets are overloaded. To clear the overload, unplug some of your equipment from the battery-supported outlets and run the self-test until the icon is no longer illuminated and the alarm is no longer sounding.

CAUTION! Any overload that is not corrected by the user immediately following a self-test may cause the UPS to shut down and cease supplying output power in the event of a blackout or brownout.

LCD Dimmer: Adjusts the brightness of the LCD Status Screen.

USB Charging Port

USB Charging Port (select models only): Charge-only USB port that delivers up to 750mA of charge current for use with cell phones, Smartphones, MP3 players and other devices that are compatible with USB chargers. Note: This port is intended for USB charging only. USB communication is not accessible through this port.

Basic Operation (Rear Panel)

Surge-Only Protected Outlets: Provide surge and line noise protection, not battery backup. Plug equipment that does not require battery backup during a utility power failure (such as a printer, scanner or fax machine) into these outlets.

Surge-Only Protected Outlets

Battery Backup Protected/Surge Protected Outlets: Provide both battery backup and surge protection. Plug your computer, monitor and other critical equipment into these outlets. NOTE: DO NOT PLUG LASER PRINTERS INTO THESE OUTLETS.

Battery Backup/Surge

Protected Outlets

USB Port

Tel/DSL Jacks

USB Communication Port (HID Compliant): This port can connect your UPS to a computer in order to automatically save open files and shut down the computer if it is left unattended during an extended power failure. Use with Tripp Lite's PowerAlert software and appropriate USB cable. A PowerAlert CD and/or USB cable are included with select models. If PowerAlert is included with your model, insert the CD into the CD tray of your computer and follow the installation instructions. If PowerAlert software and/or the appropriate cable did not come with your UPS, you can obtain the software FREE via the Web at www.tripplite.com. Any user- supplied USB cable may be used to connect your UPS to your computer. Note: This connection is optional. The UPS will work properly without this connection. Also Note: This UPS System automatically provides basic communication compatibility with many integrated Windows®, Macintosh® and Linux® power management applications.

Tel/DSL Protection Jacks (select models only): RJ-style jacks protect connected equipment by stopping surges on a single phone, fax or modem line. Connect a phone cord from the wall jack directly to the Tel/DSL jack labeled “IN.” Connect a phone cord from the Tel/DSL jack labeled “OUT” directly to the device to be protected. The UPS system must always be the first item connected in line from the wall jack. The UPS system must be plugged into a 3-wire grounded AC outlet for Tel/DSL line surge protection to work. Connecting your equipment to these jacks is optional. Your UPS will work properly without this connection.

5

201011078 93-3003.indd 5

11/12/2010 1:57:19 PM

Page 5
Image 5
Tripp Lite G1010USB owner manual Basic Operation Rear Panel