Theory of Operation    4-3 
Old Error Code  New Error 
Code  Warm-
Up  While 
Cooking  Self-
Test  Reference 
Chapter 
BLOWER STATUS  F3 BLOWER  X 
X 
X  8 
LOW COOK TMP  F2 LOW TEMP
X 
   8 
LOW MAG CURR  F3 MAG CURR
X 
X  9 
DOOR MONITOR  F4 MONITOR 
   X    
7 
MAG OVER TMP  F5 MAG TEMP
X 
X 
X  9 
ELEC OVR TMP  F6 EC TEMP  X  X   X  6 
HX RISE LOW  Same  X     X  8 
THERMO OPEN  Same  X 
X 
X  8 
OVEN DOOR AJAR  Same  X 
X 
X  7 
EC TEMP HIGH  F6 EC TEMP  X  X  X  6 
CLOSE OVEN 
DOOR  same  X  X   X  7 
TABLE 4-1
Notes:  
1. All Fault Codes listed in BOLD will terminate a Cook Cycle upon discovery. 
2. Any fault occurrence during Cook mode will be logged in the Fault Counter. 
3.  ELEC  OVR  TMP/EC  TEMP  HIGH/F6  fault  code  will  not  terminate  a  cook  cycle, 
however it will alert the user of a possible air circulation problem (Page 6-10)