TurboChef Technologies, Inc. C Series
9-10
WARNING!! Use extreme caution when taking an y current readings. Failure to d o so can result in death or serious injury.
4 5

FILAMENT TRANSFORMER

1
2
3
4
1
3
2

820MW3 ANODE TRANSFORMER

T2 FILAMENT TRANSFORMER

T1 ANODE TRANSFORMER

REAR VIEW

REAR VIEW

FRONT VIEW

5
6
750 HZ
60 HZ
1
2
3
1
50 HZ
7
6
5
4
5
2
F
3
4
60 HZ
FA208-240 VAC
INPUT MAGNETRON
4500 VPK, 415 MA
15 KV
HV DIODE
1.05 uF (60 HZ)
1.20 uF (50 HZ)
HV CAPACITOR
PRIMARY COMMON
240 VAC
200-208 VAC
UNUSED
WINDING
(4-5) 4.6 VAC SECONDARY
0.20 OHMS
PRIMARY COMMON
(1-3) 240 VAC
27.8 OHMS
(1-2) 200-208 VAC
23.2 OHMS
HV ANODE WINDING (SECONDARY)
(5-6) 60 HZ 46.39 OHMS
(5-7) 50 HZ 54.00 OHMS
(3-4) UNUSED
FILAMENT
WINDING
(1-2) 208-240 VAC
0.58 OHMS
TRANSFORMERS.DWG
FIGURE 9-4 Transformer Testing