 Cook Door 
7-5 
13. Actuator tab s hould be positioned as shown 
in  Figure  7-5. It  should  be  parallel  to  the 
primary  switch  lever.    Adjust  and  b end 
(needle  nose  pliers)  actuator  tab  as 
necessary. 
14. When  the  door is  closed  and the  actuator 
tab  is  in  contact  with  the  primary  and 
monitor switches  the  switches should  both 
be closed.    The  actuator tab  should  be in 
contact  with th e switch  paddles  such  that 
when the switches are closed there is about 
0.020”  of  clearance  between  the  switch 
paddles  and the  switch  bodies.   Also,  the 
actuator  tab  should  be  at  or  close  to 
horizontal and  be positioned  approximately 
1/4”  from  the  end  of  the  monitor  switch 
actuator  tab.    Adjust  the  interlock  switch 
brackets  by  loosening  the  scre ws  as 
necessary.  See Figure 7-5.   
15. Once  the  switches  and  actuator   are 
properly  adjusted,  as  the  door  is  opened 
the primary switch should diseng age before 
the monitor switch. 
LIMIT SWITCH ADJUSTMENT:  SECONDARY 
16. Refer  to  steps 8,  9, 10,  and  11 this  page.  
The trailing  arm must be  properly engaged 
in the  cam  follower  bracket ass embly and 
the trailing arm guide blocks. 
17. Again,  the  actuator  tab  shoul d  be 
positioned as shown  in detail of Fig ure 7-5.  
Adjust  and  bend  (needle  nose  pliers) 
actuator tab as necessary. 
18. When the  door is closed, the actuator tab is  
in contact with the second ary switch paddle 
and  the  switch  should  be  closed.  There 
should  be  approximately  0.020”  of 
clearance  between  the switch  paddle  and 
the  switch  body.    Adjust  the  limit  switch 
bracket  by  loosening  the  scr ews  as 
necessary. 
FINAL  TESTING  OF  DOOR  SWITCH 
ADJUSTMENT: 
19. After the door  switch assemblies have been 
properly  aligned  and  adjusted  on  both 
sides, confirm that with the  door closed that 
all three switches contacts are closed. 
20. As  the  door is  opened  slowly conf irm that 
all  three  switches  operate  in  the  correct 
sequence,  i.e.  as  the d oor  is opened  the 
switches  open  in  the  order  of  primary, 
secondary, and then monitor .   
21. As  the  door  is  slowly  closed  confirm  the 
switches  close  in the  opposite  order  from 
above.   
22. If  the  s equencing  is  not  correct,  readjust 
switch  brack ets  and  or  associated 
hardware until all criteria are met. 
SWITCH TEST AT TEMPERATURE: 
23. Reinstall main  circuit breaker on din rail and 
reattach wiring to bottom of circuit breaker. 
24. Reattach left  side trim piece and magnetron 
plenum assembly. 
25. Refit  top  cover  and  left  and  right  side 
covers. 
26. Plug the  oven in and set the tem perature to 
525 F  and  allow  the oven  to  come up  to 
temperature and  remain at  temperature for 
15 minutes. 
27.  Refer  to Chapter  5, and  put  the oven  into 
test mode.   At the bottom  left of the screen 
are the  letters  P, S,  and  M.   As  the  oven 
door  is slowly  opened,  the  background  of 
the  letters  will  light  up  indicating  that  the 
switches have opened. 
28. Slowly  open and  close the  door to  confirm 
the proper  sequence of the  switches, P,  S, 
M and M, S, P respectively. 
29. If the  sequencing is not correct, rem ove the 
left  and  right  side  covers  and   adjust  the 
switch brackets as necessary and retest the 
oven. 
30. If the sequencing  is correct, while in the test 
mode refer  to  section 9-2  and perform  the 
microwave radiation leakage tests.