TurboChef Technologies, Inc. C Series 
8 - 9
Delta Blower Motor Controller Fault Codes & TroubleshootingFault 
Name 
 Fault Descriptions Corrective Actions 
ocA  Over-current during acceleration: 
1. Short-circuit at motor output. 
2. Torque boost too high. 
3. Acceleration time too short. 
4. AC drive output capacity is too small.  
1. Check for possible poor insulation at the 
output line. 
2. Decrease the torque boost setting in 
Pr.7-02. 
3. Increase the acceleration time. 
4. Replace with the AC drive with one that 
has a higher output capacity (next HP 
size). 
Ocd  Over-current during deceleration: 
1. Short-circuit at motor output. 
2. Deceleration time too short.  
3. AC drive output capacity is too small. 
1. Check for possible poor insulation at the 
output line. 
2. Increase the deceleration time.  
3. Replace with the AC drive with one  
Ocn  Over-current during steady state operation: 
1. Short-circuit at motor output. 
2. Sudden increase in motor loading. 
3. AC drive output capacity is too small. 
1. Check for possible poor insulation at the 
output line. 
2. Check for possible motor stall. 
3. Replace with the AC drive with one that 
has a higher output capacity (next HP 
size). 
EF  The external memory IC can not be programmed  1. When the external terminal EF-GND is 
closed, the output will be turned off. 
(Under N.O E.F) 
cFI  Internal memory IC can not be programmed.  1. Switch off power supply. 
2. Check whether the input voltage falls 
within the rated AC drive input voltage. 
3. Switch the AC drive back on. 
cF2  Internal memory IC can no be read.  1. Check the connections between the 
main control board and the power board 
(internal to motor controller). 
2. Reset drive to factory defaults 
cF3  Drive's internal circuitry abnormal.  1. Switch off the power supply. 
2. Check whether the input voltage falls 
within the rated AC drive input voltage. 
Switch on the AC drive. 
HPF  Hardware protection failure  1. Return to the factory. Replace 
controller. 
codE  Software protection failure  1. Return to the factory. Replace 
controller. 
cFR  Auto accel/decal failure  1. Do not use the function of auto 
acceleration/deceleration. 
GF  Ground fault: 
The AC drive output is abnormal. When the output terminal is 
grounded (short circuit current is 50% more than the AC drive rated 
current), the AC drive power module may be damaged. The short 
circuit protection is provided for AC drive protection, not user 
protection. 
Ground fault: 
1. Check whether the IGBT power module 
is damaged. 
2. Check for possible poor insulation at the 
output line. 
CEI  Communication Error  1. Check the connections between the AC 
drive and computer for loose wires. 
2. Check if the communication protocol is 
properly set. 
bb  External Base Block. AC drive output is turned off.  1. When the external input terminal (B.B) 
is active, the AC drive output will be turned 
off. 
2. Disable this connection and the AC 
drive will begin to work again.