High and Low shelving filters

 

 

LMS-D26

In A Freq

Slope

Gain

EQ1 100Hz

12dB

0.0dB

a

b

c

 

 

 

a

b

c

Knob A: Frequency, 10.0Hz to 25.6kHz in variable steps

Knob B: Slope, 6 to 12dB / octave in 1dB steps

Knob C: Gain, +/-15dB in 0.2dB steps

The frequency is specified as point where the filter deviates by 3dB from the gain value.

Parametric filters

 

 

LMS-D26

In A Freq

Width

Gain

EQ1 100Hz

1.4Q

0.0dB

a

b

c

 

 

 

a

b

c

Knob A, Centre Frequency, 10.0Hz to 25.6kHz in variable steps

Knob B, Width, display selectable, Q or BW (Bandwidth)

BW adjustable from 0.05 to 5 octaves in variable steps

Q adjustable from 14.2 to 0.2 in variable steps

Knob C, Gain, +/-15dB in 0.2dB steps