Lower the horn assembly into the cabinet and replace the grille, ensuring that the nylon cup washers are replaced before tightening the fixing screws.

Removal of the low-mid frequency drive units

These can be accessed by removing the curved doors on the rear of the cabinet.

To ensure an airtight seal the access doors are fitted with a neoprene gasket. These should be regularly checked to ensure the seal is tight as the gasket can “settle” over time. Once the gasket has settled tightness should be regularly checked as during regular maintenance by ensuring the seal is maintained.

General Maintenance

Cabinets should be inspected regularly as part of a routine maintenance procedure, paying particular attention to the flying hardware and fixings. Aspect enclosures should be inspected after every tour, or during the festival season after all outdoor gigs. Simple and regular application of paint with a roller will ensure the enclosures have the longest lifespan possible without permanent damage to the enclosures.

TA-890 enclosures are fitted with stainless steel fixings. However note that even stainless steel is liable to corrosion and particular care should be taken not to burr screw heads thereby removing surface coating which might accelerate the corrosion process. A regular prgramme of inspection, and where necessary replacement, will ensure that cabinets have a long and safe working life.

Flying hardware

All flying hardware is fully tested before assembly and covered by load test certificates (a sample is reproduced earlier in this manual). Individual test certificates are available upon request.

Regular inspection by a qualified and competent lifting engineer is necessary to ensure the longevity and safety of the system.