4.Clean the condenser coil (Figure 13, 2) using a soft brush with a “combing” action or vacuum cleaner. Do not touch the condenser coil.
| 1 |
| 2 |
3 | ULIN_0159_A |
Figure 14
5.Place the
6.Secure, but do not overtighten both grille screws (Figure 14, 3).
7.Reconnect power to unit.
Leveling
It is important that units equipped with adjustable feet are level, for proper door and ice maker (if equipped) operation.
To level units with adjustable feet:
1 |
ULIN_0183_A |
Figure 15
1.Use a level to check the levelness of the unit from front to back and from side to side. Level should be placed along top edge and side edge as shown (Figure 15).
1 |
ULIN_0042_A |
Figure 16
2.If the unit is not level, adjust the feet on the corners of the unit as necessary (Figure 16).
3.Check the levelness after each adjustment and repeat the previous steps until the unit is level.
Door Alignment Check and Adjustment
IMPORTANT
Properly aligned, the door’s gasket should be firmly in contact with the cabinet all the way around the door (no gaps). Carefully examine the door’s gasket to assure that it is firmly in contact with the cabinet. Also make sure the door gasket is not pinched on the hinge side of the door.
ULIN_0143_A
Figure 17
1.Loosen (do not remove) top (Figure 17) and bottom hinge screws.
2.Align door squarely with cabinet.
3.Make sure gasket is firmly in contact with cabinet all the way around the door (no gaps).
4.Tighten bottom hinge screws.
5.Tighten top hinge screws.