To defrost:
1.Turn unit off.
2.Remove all products from the interior and prop the door in an open position (2 in. (5 cm) minimum).
3.Allow the frost to completely melt naturally. Clean the interior and all removed components using a mild non- abrasive detergent and warm water solution applied with a soft sponge or
4.Dampen a soft sponge or
5.When the interior is dry, turn unit back on.
Condenser Cleaning
Interval - Every Three Months
To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser every three months. Depending on environmental conditions, more or less frequent cleaning may be necessary.
WARNING
Disconnect electric power to the unit before cleaning the condenser.
WARNING
DO NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged.
IMPORTANT
DO NOT use any type of cleaner on the condenser unit.
Model 1115WC
1.Disconnect power to the unit.
1
3
2
ULIN_0155_A
Figure 10
2. Loosen the two screws (Figure 10, 1) completely.
NOTE: Screws are held in the grille by
3.Remove grille (Figure 10, 2) and grille cap (Figure 10, 3) from unit.
1 |
ULIN_0156_A |
Figure 11
4.Clean the condenser coil (Figure 11, 1) using a soft brush with a “combing” action or vacuum cleaner. Do not touch the condenser coil.
1
2
3
ULIN_0157_A
Figure 12
5.Make sure grille cap (Figure 12, 1) is behind grille in slots (Figure 12, 2) provided in grille before attaching grille to unit, and secure, but do not overtighten both grille screws (Figure 12, 3).
6.Reconnect power to the unit.
Model 1175WC
1. Disconnect power to unit.
2 | 1 |
| |
| ULIN_0158_A |
Figure 13
2. Loosen the two screws (Figure 13, 1) completely.
NOTE: Screws are held in the grille by
3. Remove grille from unit.
14 | 1115WC, 1175WC |