U-Line 2015WCOL manual Other Site Requirements, Power Supply, Environmental Requirements

Models: 2015WCOL 2015WC

1 16
Download 16 pages 46.2 Kb
Page 6
Image 6
Other Site Requirements

2015WC/2015WCOL Wine Captain®

 

 

2.Remove plastic screw plugs (3 each, top and bottom) from new hinge location. Do not discard (see Figure 6).

7. With bottom of door facing up, remove pivot plate

(2 screws), flip over, and remount on opposite side of

door (see Figure 9). Be sure angled side of plate faces

center.

Figure 5

Screw Plugs

Figure 6

Figure 9

3.Remove top hinge (3 screws), reinstall hinge screw pin, and remount on opposite side BOTTOM (see Figure 7).

4.Remove the two door closer inserts from the existing bottom hinge and install as shown on the new bottom hinge (see Figure 8).

8.Holding door upright with top of door tilted forward, place hole of door pivot plate on bottom hinge screw pin (see Figure 10).

9. Tilt top of door into

position in top hinge and

install top hinge screw pin.

Hinge

Screw

Pin

Figure 7

Door

Closer

Inserts

Figure 8

10. Install plastic screw plugs

removed in Step 2 in old

hinge holes (3 each, top

and bottom).

Other Site Requirements

5.Remove existing bottom hinge (3 screws) and remount on opposite side TOP. Remove hinge screw pin.

6.Remove the plastic hole plug from the top of the door to allow the pivot pin to be inserted in the new location. Install the plug into the vacated hole on the opposite side.

Power Supply

The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A circuit (normal household current). See Electrical Specifications on Page 13.

Environmental Requirements

The surrounding air temperature must be at least 50°F (10°C) but must not exceed 110°F (40°C). The unit must not be located near heat-generating equipment or in direct sunlight.