Condenser Cleaning

To defrost:

1.Turn unit off.

2.Remove all products from the interior and prop the door in an open position (2 in. (5 cm) minimum).

3.Allow the frost to completely melt naturally. Clean the interior and all removed components using a mild non- abrasive detergent and warm water solution applied with a soft sponge or non-abrasive cloth. NOTE: DO NOT use any solvent-based or abrasive cleaners. They will discolor or damage the interior.

4.Dampen a soft sponge or non-abrasive cloth in clean water and wipe down the cabinet interior and removed components to remove any detergent residue. Rinse the sponge or cloth in clean water and repeat as necessary until the cabinet and components are clean.

5.When the interior is dry, turn unit back on.

Condenser Cleaning

Interval - Every Three Months

To maintain operational efficiency, keep the front grille free of dust and lint and clean the condenser every three months. Depending on environmental conditions, more or less frequent cleaning may be necessary.

Interval - Every Three MonthsWARNING

Disconnect electric power to the unit before cleaning the condenser.

To remove and replace the grille for access to the condenser fins, follow this procedure:

1

2

ULIN_0203_A

Figure 9

1.Disconnect electrical power to the unit.

2.Loosen two screws (Figure 9, 1) completely.

NOTE: Screws are held in the grille by o-ring retainers, and will not come free of the grille.

3. Remove the grille.

LevelingWARNING

DO NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged.

Manual backgroundCAUTION

DO NOT use any type of cleaner on the condenser unit.

4.Clean the condenser coil (Figure 9, 2) using a soft brush with a “combing” action or vacuum cleaner. Do not touch the condenser coil.

5.Position the grille to align the mounting screws with the holes in the cabinet.

6.Secure, but do not over-tighten both grille screws.

7.Reconnect power to the unit.

Leveling

1

ULIN_0833_A

Figure 10

1.Use a level to check the levelness of the unit from front to back and from side to side. Level should be placed along top edge and side edge as shown (Figure 10).

1

ULIN_0044_A

 

Figure 11

2.If the unit is not level, adjust the feet on the corners of the unit as necessary (Figure 11).

3.Check the levelness after each adjustment and repeat the previous steps until the unit is level.

14

2175BEVS, 2175BEVOL

Page 14
Image 14
U-Line manual Condenser Cleaning, Leveling, Interval - Every Three Months, 2175BEVS, 2175BEVOL