QUICK START GUIDE
NOTICE
Drain can NOT be located directly below the unit. Unit has a solid base that will not allow the unit to drain below itself.
There is a possibility that hose connections may have loosened during shipment.
Verify all connections and fittings are free from leaks.
GRAVITY DRAIN
Normal
Proper Drain
With Trap
Poor Drainage, Water Will Back Up
With Trap and Vent
Proper Drain
A gravity drain may be used if:
Drain line has at least a 1" drop per 48" (approximately 2 cm drop per 100 cm) of run.
Drain line does not create traps and is vented per local code.
1.Cut the
2.Connect to your local plumbing per the local code.
3.If necessary, insulate drain line to prevent condensation.
!CAUTION
Failure to connect water supply or drain line connections properly can result in personal injury and property damage. Gravity drain connections must be routed downward from the rest of the unit at the rate of 1/4" per foot (1 cm per 50 cm).
FACTORY INSTALLED DRAIN PUMP
If your drain line will run up to a stand pipe, disposal or spigot assembly, or does not otherwise meet the requirements for a gravity drain, you may have ordered a
See below for typical installations requiring a drain pump.
Stand Pipe
P60 Pump Required
Waste
6KXW2ɞ Valve
Cold
Hot Water
Water
Waste
6