U-Line CO75, CO29 manual Leveling, Door Alignment Check and Adjustment

Models: CO75 CO29

1 24
Download 24 pages 49.65 Kb
Page 13
Image 13
Leveling

IMPORTANT

Use only genuine U-Line replacement parts. U-Line ice maker parts are not the same as standard FSP Whirlpool parts. Using non U-Line parts can reduce ice rate, cause water to overflow from ice maker mold, damage the unit, and may void the warranty.

Leveling

It is important that units equipped with adjustable feet are level, for proper door and ice maker (if equipped) operation.

NOTE: Model CO29 DOES NOT have leveling feet. This model MUST be placed on a level surface to operate properly.

To level units with adjustable feet:

1

ULIN_0225_A

Figure 17

1.Use a level to check the levelness of the unit from front to back and from side to side. Level should be placed along top edge and side edge as shown (Figure 17, 1).

1

ULIN_0042_A

Figure 18

2.If the unit is not level, adjust the feet on the corners of the unit as necessary (Figure 18).

3.Check the levelness after each adjustment and repeat the previous steps until the unit is level.

Door Alignment Check and Adjustment

IMPORTANT

Properly aligned, the door’s gasket should be firmly in contact with the cabinet all the way around the door (no gaps). Carefully examine the door’s gasket to assure that it is firmly in contact with the cabinet. Also make sure the door gasket is not pinched on the hinge side of the door.

ULIN_0210_A

Figure 19

NOTE: Model CO75 shown (Figure 19)

1.Loosen (do not remove) top (Figure 19) and bottom hinge screws.

2.Align door squarely with cabinet.

3.Make sure gasket is firmly in contact with cabinet all the way around the door (no gaps).

4.Tighten bottom hinge screws.

5.Tighten top hinge screws.

CO29, CO75

13

Page 13
Image 13