Ultra electronic 155, 105, 80 manual Dimensions, GAS-FIREDWATER BOILER SERIES 2 - Boiler Manual

Models: 230 & -310 105 155 80

1 44
Download 44 pages 30.46 Kb
Page 43
Image 43
10 GAS-FIRED WATER BOILER SERIES 2 — Boiler Manual

10DimensionsManual backgroundManual background GAS-FIRED WATER BOILER SERIES 2 — Boiler Manual

Dimensions

Notes 1. Boiler supply and return tappings are both 1" NPT (Ultra-

and 1¼" circulator flanges are shipped with boiler on Ultra-

80/105/155/230) or 1¼" NPT (Ultra-310). See pages 14

80/105/155/230. Both 1¼" and 1½" circulator flanges are

through 18 for recommended system supply and return

shipped with boiler on Ultra-310.

piping sizes. Wall-hung boilers: water piping and gas pipe

3. Relief valve is shipped loose. See page 11 for mounting

can be routed through bottom of enclosure using wall-

details. Relief valve mounts on supply pipe off of supply

mounting kit.

tee and ¾" street elbow as shown.

 

2. Boiler circulator is shipped loose. Circulator may be

 

mounted on either boiler supply or return piping. Both 1"

 

Part number 550-100-026/0404

43

Page 43
Image 43
Ultra electronic 155, 105, 80, 230 & -310 manual Dimensions, GAS-FIREDWATER BOILER SERIES 2 - Boiler Manual