7.If you selected ED-SCTin Step 3, stop here.

Otherwise, if you selected ED-HIor ED-LOin Step 3, follow these steps to enter the talk group ID (agency, fleet, and subfleet) for the system you want to scan.

a.Press DATA.

b.If necessary, turn the rotary tuner or repeatedly press HOLD U or LIMIT V until PRO9 ID appears. Then press E on the keypad.

c.Turn the rotary tuner or repeatedly press HOLD U or LIMIT V until the talk group ID memory location where you want to store an ID appears.

d.Use the keypad to enter the agency, fleet, and subfleet, then press E. (Press . to enter the hyphen).

e.To enter additional IDs, repeat Steps c-d.

Programming LTR Systems

1.Hold down TRUNK for about 2 seconds. The scanner beeps and BANK, TRUNK, and the bank letters A-J blink.

2.Press a bank key to select the bank where you want to store the frequencies.

3.Select LTR scanning by turning the rotary tuner or repeatedly pressing HOLD U or LIMIT V to select LT. Then press E on the keypad.

4.If necessary, repeatedly press HOLD U or LIMIT V until PRO9 F appears. Then press E on the keypad.

5.To enter trunking frequencies, use the keypad to enter the first frequency, then press E on the keypad. (Press . to enter the decimal point).

Note: To clear a mistake while entering a frequency, press . twice then enter the frequency again.

6.For each additional frequency, select the next channel by turning the rotary tuner or pressing HOLD U. Then use the keypad to enter the next frequency, then press E on the keypad. (Press . to enter the decimal point).

7.Follow these steps to enter the talk group ID (agency, fleet, and subfleet) for the system you want to scan.

a.Press DATA.

b.If necessary, turn the rotary tuner or repeatedly press HOLD U or LIMIT V until PRO9 ID appears. Then press E on the keypad.

c.Turn the rotary tuner or repeatedly press HOLD U or LIMIT V until the talk group ID memory location where you want to store an ID appears.

d.Use the keypad to enter the agency, fleet, and subfleet, then press E. (Press . to enter the hyphen).

e.To enter additional IDs, repeat Steps c-d.

45