Steamers must be leveled front to back, or pitched to the rear (maximum ¼ inch) by adjusting the bullet feet on the stand.

A 2 inch ID hose may be attached to the unit drain. It must be rated for very hot water.

WARNING

DO NOT CONNECT THE UNIT DRAIN DIRECTLY TO THE BUILDING DRAIN.

Ensure that there is a free air gap between the end of the unit drain and the building drain. This gap should be as close as possible to the unit drain. Do not allow elbows or restrictions between the unit and the free air gap.

CAUTION

DO NOT USE PLASTIC PIPE. DRAIN MUST BE RATED FOR VERY HOT WATER.

Install the line with a constant downward pitch.

Proper Drain Line Connection - Drain Line must have a constant downward pitch of at least 1/4" per foot. (2)HY-5G shown.