OM-HY-5G
Initial
After the
1.Remove all literature and packing materials from the interior and exterior of the unit.
2.Make sure the water supply line is open.
3.Make sure that the gas supply line is open and that the manual knob on the main gas valve is turned to the “on” position. This valve is located behind the front access panel on the right side of the unit.
4.Turn on electrical service to the unit. The
5.The steamer will not operate until the pilot burner has been ignited. To light the pilot burner, activate the pilot switch located behind the sliding door located on the right cover panel. When the pilot ignition sequence has been successfully completed, a green light - on the pilot switch will glow.
6.The “trial for ignition” period is roughly 90 seconds. If the pilot burner does not light within about 90 seconds after the switch is activated, the ignition system automatically stops gas flow to the pilot burner and stops the ignition trial. If this happens, turn off the pilot switch and repeat the trial for ignition.
During the initial
NOTE: See Automatic Operation of Pilot at the end of this section.
7.Once the pilot burner flame has been established (the green light on the pilot switch is on), press the “ON” switch for the desired steamer cavity. The steam generator will fill with water.
NOTE: The door MUST be closed for the main (high) burner to work.
8.When the steam generator has filled with water, the low and main burners will ignite automatically. Within
water has reached its standby temperature. When the READY light is displayed, you may take any one of the following steps:
a.Set the timer to the desired time for timed steaming.
b.Turn the timer knob to the manual ON position for continuous steam.
c.Let the unit stay at standby temperature.
WARNING
WHEN YOU OPEN THE DOOR, STAY AWAY FROM STEAM COMING OUT OF THE UNIT. THE STEAM CAN CAUSE BURNS.
9.To shut down the unit, press the ON switch into the off position. The steam generator will then drain. You may also switch off the pilot switch to conserve energy.
10.If the
Automatic Operation of Pilot
Once the pilot burner is lit, it essentially functions as a standing pilot. In this state, if the pilot is accidentally extinguished (by a very strong gust of wind for example), it will
After the unit has been running, if the pilot burner ever fails to
NOTE: For operation at high altitudes (2000 feet and above) please consult the Groen Food Service Engineering Department.