OM-HY-5G
Maintenance
The
Always supply water with a low mineral count that meets the standards outlined in the Water Quality and Treatment section of this manual.
If steam or condensate is seen leaking from around the door, take the following steps:
1.Check the door gasket. Replace it if it is cracked or split.
2.Inspect the cooking chamber drain to be sure it is not blocked.
3.Adjust the door latch pin to allow for changes that might occur as the gasket ages.
a.Loosen the lock nut at the base of the latch pin, then turn the latch pin ¼ turn clockwise, and tighten the lock nut.
b.After adjustment, run the unit to test for further steam leakage.
c.If there is still leakage, repeat the adjustment.
d.Continue adjusting the pin clockwise until the door fits tightly enough to prevent leakage. The hinge may also be adjusted.
Troubleshooting
This Groen Steamer is designed to operate smoothly and efficiently if properly maintained. However, the following is a list of checks to make in the event of a problem. Wiring diagrams are furnished inside the service panel. If an item on the check list is marked with (x), it means that the work should be done by a
SYMPTOM | WHO |
| WHAT TO CHECK |
| (If item is marked X, work should be done by a factory authorized service rep) | ||
Pilot will not light | User | a. | Are electrical connections made with a ground? |
|
| b. | Is gas supply connection made? |
|
| c. | Is pilot ignition switch on? |
|
| d. | Is gas valve turned on? |
|
| e. | Are building fuses or circuit breakers all right? |
|
| f. | Are there drafts which could blow out the pilot? |
| Auth Service | g. | Is spark ignition cable connected to module? (X) |
| Rep Only | ||
|
|
| |
Steam generator does not fill with | User | a. | Is the ON switch depressed? |
water. |
| b. | Is the water supply connected? |
|
| c. | Is the water turned on? |
|
| d. | Check for low water pressure (less than 30 PSI or |
|
| e. | 210 kPa). |
|
| Is the screen at the water connection clogged? | |
|
| f. | Has the steam generator been delimed? |
No steam. | User | a. | Is the ON switch depressed? |
|
| b. | Is the water supply connected? |
|
| c. | Is the water turned on? |
|
| d. | Are steamer doors open? |
|
| e. | Is the steam generator limed up? |
Service light comes on after four | User | a. | Is the water supply connected? |
minutes. |
| b. | Is the water turned on? |
|
| c. | Has the unit been delimed? (Refer to Cleaning |
|
|
| Section) |
Excessive steam escaping from rear | User | a. | Is the water spray hose kinked or obstructed? |
of unit | Auth Service | b. | Is the water spray solenoid connected?(X) |
| Rep Only | c. | Is the drain properly vented? (X) |
14