Maintenance and Troubleshooting

Maintenance and Troubleshooting

The lamp should be replaced when it reaches the end of its life (typically between 2000 and 2500 hours depending on the Lamp Power setting), or sooner if a noticeable degradation in brightness occurs. Contact your Planar dealer to obtain a replacement lamp.

1.Turn off the projector and unplug the power cord. Allow the projector to cool down for approximately 60 minutes prior to removing the lamp assembly for replacement.

2.Using a flat-blade screwdriver,

loosen the four screws holding the rear compartment cover in place.

5.1

Lamp Replacement

￿￿ ￿￿

3.Remove the rear compartment cover by tilting it upward.

4.Loosen the screw on the lamp cover and pull the lamp cover out.

5.Loosen the two screws on the lamp module.

6.Pull the lamp module handle firmly to remove the lamp module.

7.Perform Steps 6 through 2 (in reverse order) to install the new lamp module.

8.Turn on the power and reset the lamp timer.

￿

￿

￿

￿￿