Vanguard Heating VN18TA Continued, Lighting Instructions, Control Knob In The OFF, Pilot, VP16TA

Models: VP26TA VN30A VN18TA VP22ITA VN30TA VN18A, VN18TA, VP16A, VP16TA, VP26A, VP26TA, VN30A, VN30TA, VP16ITA, VP22ITA VP26A VP16ITA VP16A VP16TA

1 36
Download 36 pages 12.49 Kb
Page 16
Image 16
Figure 22 - Control Knob In The OFF

OPERATING HEATER

Continued

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information, page 15, column 2.

2.Make sure equipment shutoff valve is fully open.

3.Turn thermostat control knob clockwise

Clockwise to the OFF position (see Figure 22 or 23 for your model).

4.Wait five minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, page 15, column 2. If you don’t smell gas, go to the next step.

5.Turn thermostat control knob counter- clockwise C-clockwiseto the PILOT position.

Press in thermostat control knob for 5 sec- onds (see Figure 22 or 23 for your model). Note: You may be running this heater for the first time after hooking up to gas supply. If so, you may need to press in thermostat control knob for 30 seconds or more. This will allow air to bleed from the gas system.

If thermostat control knob does not pop up when released, contact a qualified ser- vice person or gas supplier for repairs.

6.Keep thermostat control knob pressed in while pushing down and releasing the ignitor but- ton. This will light pilot. If necessary, continue to press ignitor button until pilot lights.

If pilot does not light

turn thermostat control knob clockwise

Clockwise to the OFF position

• repeat steps 5 and 6

If pilot does not stay lit after several tries

refer to Troubleshooting, pages 20 through 22

contact a qualified service person or gas supplier

Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 17.

7.Keep thermostat control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety inter- lock system. Wait one minute before light- ing pilot again.

8.Turn thermostat control knob counter- clockwise C-clockwiseto the desired heating level. For models, VP16TA, VN18TA, VP26TA, and VN30TA, the main burner should light. Set control knob to any heat level between 1 and 5 (see Figure 25). For infrastat models, the plaque directly above the pilot should light.

Position, Models VP16TA, VN18TA, CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

Ignitor Button

Control Knob

 

 

F

 

FO

Figure 22 - Control Knob In The OFF

Position, Models VP16TA, VN18TA,

VP26TA, & VN30TA

Plaque Control

Ignitor

Thermostat

Button

Control Knob

Knob

 

 

1

2

3Figure 24 - Pilot

4

Figure 23 - Thermostat Control Knob In The OFF Position, Models VP16ITA & VN22ITA

Thermocouple

VP16TA Ignitor Electrode

Pilot Burner

 

 

Figure 24 - Pilot

 

Control

VP16TA

 

 

VP26TA

 

Knob

VN18TA

 

 

VN30TA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 25 - Burner Patterns

16

www.desatech.com

113052-01A

Page 16
Image 16
Vanguard Heating VN18TA, VP26A Continued, Lighting Instructions, Control Knob In The OFF, Pilot, VP16TA, VP26TA, VN30TA