Vanguard Heating VP16ITA, VP26A WARNING If you smell gas Shut off gas supply, Continued, Remedy

Models: VP26TA VN30A VN18TA VP22ITA VN30TA VN18A, VN18TA, VP16A, VP16TA, VP26A, VP26TA, VN30A, VN30TA, VP16ITA, VP22ITA VP26A VP16ITA VP16A VP16TA

1 36
Download 36 pages 12.49 Kb
Page 22
Image 22
 WARNING: If you smell gas

TROUBLESHOOTING

Continued

•Do not try to light any appliance. WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM POSSIBLE CAUSE

REMEDY

Heater produces a clicking/tick- ing noise just after burner is lit or shut off

1.Metal expanding while heating or contracting while cooling

1.This is common with most heat- ers. If noise is excessive, con- tact qualified service person

White powder residue forming within burner box or on adja- cent walls or furniture

1.When heated, vapors from fur- niture polish, wax, carpet cleaner, etc., may turn into white powder residue

1.Turn heater off when using furniture polish, wax, carpet cleaners, or similar products

Heater produces unwanted 1.

Heater burning vapors from

odors

paint, hair spray, glues, etc. See

 

IMPORTANT statement above

2.

Low fuel supply (propane/LP gas)

3.

Gas leak. See Warning

 

statement at top of page

1.Ventilate room. Stop using odor causing products while heater is running

2.Refill supply tank

3.Locate and correct all leaks (see Checking Gas Connec- tions, pages 12 and 13)

Heater shuts off in use (ODS

1. Not enough fresh air is

1.

Open window and/or door for

operates)

 

available

 

ventilation

 

2.

Low line pressure

2.

Contact local natural or pro-

 

 

 

 

pane/LP gas company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning

 

 

 

 

and Maintenance, page 19)

 

 

 

 

Gas odor even when control

1. Gas leak. See Warning

1.

Locate and correct all leaks

knob is in OFF position

 

statement at top of page

 

(see Checking Gas Connec-

 

 

 

 

tions, pages 12 and 13)

 

2.

Control valve defective

2.

Replace control valve

Gas odor during combustion

1.

Foreign matter between con-

 

 

trol valve and burner

 

2.

Gas leak. See Warning

 

 

statement at top of page

1.Take apart gas tubing and re- move foreign matter

2.Locate and correct all leaks (see Checking Gas Connec- tions, pages 12 and 13)

Moisture/condensation noticed

1. Not enough combustion/ven-

1. Refer to Fresh Air for Com-

on windows

tilation air

bustion and Ventilation re-

 

 

quirements (page 5)

22

www.desatech.com

113052-01A

Page 22
Image 22
Vanguard Heating VP16ITA, VP26A WARNING If you smell gas Shut off gas supply, Do not try to light any appliance, Continued