Vanguard Heating VP16ITA, VP26A Continued, Ignitor Button, Knob, Safety Device, Ignition System

Models: VP26TA VN30A VN18TA VP22ITA VN30TA VN18A, VN18TA, VP16A, VP16TA, VP26A, VP26TA, VN30A, VN30TA, VP16ITA, VP22ITA VP26A VP16ITA VP16A VP16TA

1 36
Download 36 pages 12.49 Kb
Page 4
Image 4
Continued

SAFETY INFORMATION

Continued

5.Always run heater with plaque control knob at the 1, 2, 3, or 4 locked positions. Never set control knob between locked positions. Poor combustion and higher levels of carbon mon- oxide may result.

6.This heater needs fresh, outside air ventila- tion to run properly. This heater has an Oxy- gen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Com- bustion and Ventilation, pages 5 through 7.

7.If heater shuts off, do not relight until you pro- vide fresh, outside air. If heater keeps shut- ting off, have it serviced.

8.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

9.Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

10.Turn off and unplug heater and let cool be- fore servicing. Only a qualified service per- son should service and repair heater.

11.Operating heater above elevations of 4,500 feet could cause pilot outage.

12.To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. ca- pacity.

13.Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.

14.Provide adequate clearances around air open- ings.

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

PRODUCT

IDENTIFICATION

Ignitor Button

Control

 

Knob

Grill

Guard

Ignitor ButtonKnobPlaque

Grill Front Panel

Heater Cabinet

Figure 1 - Vent-Free Gas Heater

UNPACKING

1.Remove heater from carton.

2.Remove all protective packaging applied to heater for shipment.

3.Check heater for any shipping damage. If heater is damaged, promptly return to where you bought heater.

PRODUCT FEATURES

SAFETY DEVICE

This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/ pilot is a required feature for vent-free room heat- ers. The ODS/pilot shuts off the heater if there is not enough fresh air.

IGNITION SYSTEM

This heater has an electronic ignitor to light heater fuel supply.

THERMOSTATIC HEAT CONTROL

(Thermostat Models Only)

Thermostat models have a thermostat sensing bulb and a control valve. This results in the greatest heater comfort. This can also result in lower gas bills.

4

www.desatech.com

113052-01A

Page 4
Image 4
Vanguard Heating VP16ITA Continued, Ignitor Button, Knob, Grill Guard Plaque Front Panel Heater Cabinet, Safety Device