Install the Optional Fan

Install the Optional Fan

If you are installing the optional convection Fan Kit #2767 (FK26), continue here. If you are not installing a Fan Kit, go to Page 14, Venting System Assembly.

1.The fan kit includes a Blower Assembly and a Rheo- stat Assembly, connected by a cable. (Fig. 12) The Blower Assembly mounts to the bottom rear of the stove, and the Rheostat mounts to the valve cov- erplate. The assembly includes a ‘snapstat’ which automatically turns the fan On (or Off) above (or below) approximately 109˚. The Rheostat also pro- vides a range of fan speed settings from Off (which overrides the snapstat function) to High. Unpack and inspect the Blower assembly. Confirm that the fan spins freely.

WARNING

This appliance is equipped with a three-prong (grounded) plug for your protection against shock hazard and should be plugged directly into a prop- erly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

 

Not Used on RF

Snapstat

 

Models

Bracket

 

 

Snapstat/

 

 

Extension

Not Used

Assembly

on

 

 

Dutchwest

 

 

 

Rheostat

 

 

Assembly

 

 

Not Used

 

 

on RF

 

 

Models

Blower

 

 

Assembly

 

 

 

Connect to PC Board on

ST473

 

RF Models Only

Fig. 12

Fan kit components.

 

2.Remove the rear skirt insert panel at the bottom of the Rear Skirt (Fig. 13) and fasten the blower as- sembly to the firebox back with the two Phillips pan- head bolts originally installed in the firebox back. (‘1’, Fig. 14)

3.Attach the snapstat assembly to the snapstat brack- et with two sheet-metal screws. (‘2’, Fig. 14) Attach the snapstat bracket to the stove with a hex-head bolt passing through the bracket and into the stove base. (‘3’, Fig. 14)

4.The rheostat control switch attaches to the left side of the valve bracket at the front of the stove.

Dutchwest Direct Vent / Natural Vent Gas Heater

Remove retaining nut from shaft of rheostat. (if preinstalled)

Insert the rheostat through the hole in the back of the left side of the valve bracket, aligning the locator pin with the smaller hole in that bracket.

Thread the retaining nut onto the shaft of the rheostat, tightening with a wrench. Do not over- tighten.

Attach the control knob to the rheostat shaft.

Use the wire tie to secure the fan and rheostat wire harnesses together.

Rear Skirt

 

Sheet Metal

 

Screws

 

Rear Skirt Insert

ST757

Fig. 13 Remove rear skirt insert.

 

 

Star Washer

 

Sheet Metal Screws

 

Phillips

2

Snapstat

1

 

Pan

 

1/4” - 20

Head

 

 

Hex Bolt

Bolts

 

 

 

Star

Washer

Snapstat

3 Bracket

ST314

Fig. 14 Attach the fan assembly and the snapstat.

Rheostat

Retaining Collar

Rheostat Knob

ST758

Fig. 15 Attach the fan rheostat.