Dutchwest Direct Vent / Natural Vent Gas Heater
8.Install appropriate pipe sections until the vent run reaches above the flashing. The enlarged ends of the vent sections always face downward.
9.Install the storm collar and seal around the joints. (Fig. 31)
10.Add additional vent lengths to achieve the proper overall height.
11.Apply cement to the inner and outer termination col- lars and install the terminal cap.
#7DVAIS Attic Insulation Shield
Venting System Assembly - Natural Vent
General Information
The Dutchwest Heater is shipped from the factory as a Direct Vent Heater. It may be converted to a Natural Vent heater by installing the Model Z31D00 FSDHAG Draft Hood Adapter.
The Dutchwest Heater is approved for installation as a Natural Vent. CFM Direct Vent pipe could be used directly after the Draft Hood Adapter up to the ceiling, then
NOTE: The restrictor plate supplied with the stove is not used for Natural Vent applications.
| #7DVFS | |
Use Four 8d | Firestop | |
Nails | In Upper | |
Floor | ||
|
Decorative 7”
Pipe
4”
Pipe
Draft Hood
Adapter
CFM Direct Vent System may be used Draft Hood up up to the ceiling
|
| #7DVFS |
|
| Firestop in |
ST222 |
| Ceiling |
|
| |
Fig. 30 | Install firestops and attic insulation shield. | |
|
| Sealant |
Storm Collar |
| |
|
| Upper |
|
| edge of |
|
| flange goes |
|
| under upper |
|
| shingles |
Flashing |
| |
#7DVSKV |
| |
(A, B of F) |
| |
Roof Support | ST221 | |
Fig. 31 | Roof support and flashing. |
|
18 |
|
|
ST766
Fig. 32 Decorative 7” pipe may be fitted around the
The Dutchwest stove, when installed as a Natural vent heater, includes a vent safety switch. (Fig. 60, Page
32)Operating the stove when it is not connected to a properly installed and maintained venting system, or tampering with or disconnecting the vent safety switch, can result in carbon monoxide (CO) poisoning and pos- sible death.
For U.S. installations: The venting system must con- form with local codes and/or the current National Fuel Gas Code, ANSI Z22.1.
For Canadian installations: The venting system must conform to the current CSA B149.1 installation code.
Install the Vent Pipe
Apply a bead of sealant around bottom end of inner starter pipe (found in bag with logset) and attach to stove. Apply a bead of sealant around top of inner starter pipe and install the Z31D00 FSDHAG Draft Hood according to Draft Hood instructions. (Fig. 33)