Vermont Casting 3340 Operation, Operable Doors, Your First Fire, Pilot and Burner Inspection

Models: 3356 4409 410 3340 3355 3349

1 32
Download 32 pages 59.41 Kb
Page 16
Image 16
Operation

Radiance Natural Vent Gas Heater

Operation

Operable Doors

The Radiance is shipped with the operable door front. The stove may be operated with the doors either open or closed. To open the front doors, insert the handle into the door latch stub and turn it to the right and up. (Fig. 31) When not in use, the handle may be stored in the handle holder on the right side of the rear shroud. (Fig. 32)

Counterclockwise to Open

Clockwise to Close

ST621a

Fig. 31 To open the front doors, turn handle counterclockwise.

Handle

Holder

RADIANCE

ST656

Fig. 30 When not in use, store handle in the handle holder.

Your First Fire

Read these instructions carefully and familiarize yourself with the burner controls shown on Page 16. Locate the pilot assembly, Figure 33. Follow the lighting instructions on Page 17 exactly.

During the first fire, it is not unusual to smell some odor associated with new logs, paint and metal being heated. Odors should dissipate within an hour or so, however, you can open a window to provide fresh air to alleviate the condition.

Pilot and Burner Inspection

Each time you light your heater check that the pilot flame and burner flame patterns are as shown in Figures 35 and 36. If flame patterns are incorrect, turn the heater off. Contact your dealer or a qualified gas technician for assistance. Do not operate the heater until the pilot flame is correct.

Flame & Temperature Adjustment

For units equipped with HI/LO valves, the flame adjust- ment is accomplished by rotating the HI/LO knob located near the center of the gas control valve. (Fig. 34)

Pilot Assembly

ST476

Fig. 33 Pilot Assembly location.

Turn

 

 

 

counterclockwise

LO

HI

Turn clockwise
to decrease

 

to increase

 

 

flame height

 

 

flame height

 

 

 

HV102

Fig. 34 Flame adjustment knob for Honeywell valve.

Flame Characteristics

It is important to periodically perform a visual check of the pilot and burner flames. Compare them to Figures 35 and 36. If the flame patterns appear abnormal contact a qualified service provider for service and adjustment.

 

CO105c

Fig. 35

Correct pilot flame pattern. SIT pilot.

 

 

 

 

 

 

LG157

 

 

 

 

 

 

Red Glow

 

 

 

 

 

 

 

 

Fig. 36 Correct burner flame pattern.

16

20004409

Page 16
Image 16
Vermont Casting 3340 Operation, Operable Doors, Your First Fire, Pilot and Burner Inspection, Flame Characteristics, Turn