Radiance Natural Vent Gas Heater
12.Insert blue painted screw when converting to natural gas and red painted screw when converting to LP.
13.Tighten screw (do not over tighten), replace cap.
14.Locate pilot. (Fig. 38)
15.Replace pilot orifice.
•Remove pilot hood by lifting up. (Fig. 41) NOTE: It is not necessary to remove the pilot tube for conver- sion.
Pilot Hood |
Pilot |
Bracket |
CO105a |
Fig. 41 Remove pilot hood.
•Remove pilot orifice with allen wrench. (Fig. 42)
•Install the conversion orifice.
•Reinstall pilot hood. Be sure to align hood with index tab.
Index Tab | Allen Wrench |
Snap Ring |
|
CO106a |
|
Fig. 42 Remove pilot orifice.
16.Air shutter adjustment. The unit is shipped from the factory with the air shutter open 1”. For LP units only, the air shutter could be closed further. Refer to Table 3 for minimum air shutter opening. The air shutter is located on the bottom of the burner to the left. (Fig.
43)
17.Replace burner. Slide the burner in at an angle with left side lower than the right side. Slide the left side onto the injectors, making sure the burner leg remains at a 90° angle to the base. Lower the right hand side down in to place. Make sure the burner is as far left as possible and the injector shoulders are inside the burner.
NOTE: It is very critical to keep the left burner leg, which holds the injectors, at a 90° angle to the base. (Fig. 39) This keeps the orifices aligned with the tubes inside burner. Failure to do so could affect the flame appearance and performance of the unit.
18.Place conversion label on valve.
19.Reinstall the right and left log bracket assembly. 20.Reinstall the rear log bracket.
21.Replace logs.
22.Replace glass and stove front. Conversion is complete.
Refer to Table 2 | Bottom of Burner Pan |
ST667
Fig. 43 Adjust air shutter on bottom of heater, Refer to Table 2 for correct position.
Table 2. Injector Orifice Size Matrix
|
| Conversion to Natural Gas |
| Input (BTU/h) | |||||
Kit # | Front |
| Part # | Rear |
| Part # |
| Minimum | Maximum |
#51 |
| 30000449 | #40 | 20004263 | 25,000 | 35,000 | |||
|
|
|
|
|
|
|
|
|
|
|
|
| Conversion to LP |
|
|
| Input (BTU/h) | ||
Kit # | Front |
| Part # | Rear |
| Part # |
| Minimum | Maximum |
#57 |
| 20004587 | #54 |
| 20000130 |
| 27,500 | 35,000 | |
|
|
|
|
|
|
|
|
|
|
Table 3. Air Shutter Adjustment
Model
RNVOD
Natural Gas | LP |
1¹⁄₂” | Fully Closed |
|
|
Minimum rear injector air inlet openings.
20 | 20004409 |