Vermont Casting 39LDVR Wiring Instructions, Ceramic Refractory Kits, Remote Controls, to Figure

Models: 36LDVR 33LDVR 39LDVR 43LDVR

1 40
Download 40 pages 6.57 Kb
Page 37
Image 37
Wiring Instructions

Wiring Instructions

LDVR Series Direct Vent Gas Fireplace

The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electric Code.

For USA installations follow the local codes and the national electrical code ANSI/NFPA No. 70.

Should this fan require servicing or repair the power supply must be disconnected. For rewiring of any replacement parts refer

Side Panel

FP1231

Back Panel

Log Support

Burner Tray

to Figure 53. Side Panel

to Figure 53.

Any electrical rewiring of this fan must be done by a licensed electrician.

Fan

Temperature Sen-

sor

Speed

Control

Black

White

Ground

FP1025

Fig. 53 FK24 fan wiring.

Ceramic Refractory Kits

Ceramic refractory panels are available in kit form for the LDV series appliances

Appliance Model Kit Name

33LDVR 33LDVRCR

36LDVR 36LDVCR

39LDVR 39LDVCR

43LDVR 43LDVCR

Take care when handling the refractory panels as they are fragile until held in place and supported.

Installation Refer to Figures 54 & 55

1.Remove the front window frame assembly.

2.Remove the logs.

3.Place the rear refractory panel in place. Locate the lower edge of the panel in the ledge formed by the top of the rear log support bracket.

4.Slide the side refractory panels into place to hold the rear panel secure. Repeat the procedure on the other side.

5.Replace the logs and window frame assembly.

For aesthetic purposes we recommend aligning the horizontal mortar lines.

Fig. 54 Ceramic panel installation.

Rear Refrac-

 

tory Panel

 

 

Firebox Back

Rear Panel

Panel

 

Support

 

Brackets

 

Rear Log

 

Support

 

 

FP1232

 

 

Fig. 55 Rear refractory panel installation.

 

 

 

Remote Controls

 

Optional remote control units are available to control different functions of the appliances

Model

Function/s Controlled

RCI

ON/OFF

RC2

ON/OFF and Temperature

IMTFK

Wall mounted thermostat control

(must be used in bedroom installations)

10007317

37

Page 37
Image 37
Vermont Casting 39LDVR Wiring Instructions, Ceramic Refractory Kits, Remote Controls, to Figure, Appliance Model Kit Name