Chateau™ Direct Vent Gas Fireplace
Fuel Conversion Instructions
WARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having ju- risdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper instal- lation of this kit. The installation is not proper and complete until the operation of the converted appli- ance is checked as specified in the manufacturer’s instructions supplied with the kit.
CAUTION: The gas supply shall be shut off prior to disconnecting the electrical power, before proceed- ing with the conversion.
Avertissement: Cette trousse de conversion Ne doit être installée que par le représentant d’un organ- isme qualifié et conformément aux instructions du fabricant et aux codes et exigences pertinentes de l’autorité compétente. Quiconque ne respecte pas
àla lettre les instrucitons du présent guide risque de déclencher un incendie, une explosion ou le dé- gagement de monoxyde de carbone entraînant des dommages matériels, des lésions corporelles ou la perte de vies humaines. L’organisme qualifié qui effectur les travaux est responsible de l’installation de cette trousse. L’installation n’est pas terminée tant que le fonctionnement de l’appareil converti n’a pas été vérifié selon la notice du fabricant qui accompagne la trousse.
ATTENTION: Avant d’effectuer la conversin, coupez d’abord l’limentation en gaz, ensuite, coupez l’alimentation électrique.
Conversion Precautions
Allow unit to cool if it has been operating.
Before proceeding with conversion, turn control knob on valve to OFF and turn gas supply OFF. Turn OFF any electricity that may be going to appliance.
Conversion Procedure
1.Remove glass frame. Refer to Page 28.
2.Remove lava rock, volcanic rock, embers and logs. Carefully remove brick panels.
CAUTION: Logs may be hot.
Replace Burner Orifice
1.With a Phillips or Robertson screwdriver, remove the four (4) nuts holding the fettle to the burner as- semblies. With a hex, remove the two (2) hex nuts holding each burner tube to the front of the burner assembly on both sides. Remove burner tubes.
2.Remove two (2) hex nuts holding the left burner leg. Remove burner leg. (Fig. 55)
3.Remove two (2) screws holding the pilot assembly
Hex
Nuts
KT550
Fig. 55 Use 3/8” socket to remove hex nuts holding burner legs.
to the burner assembly. Move the pilot assembly toward the back.
4.Slide the burner housing assembly to the left and away.
5.Replace the four (4) injectors. Refer to Table 1.
Replace Pilot Orifice
1.Remove pilot hood by lifting up. (Fig. 56) NOTE: It is not necessary to remove the pilot tube for conver- sion.
2.Remove pilot orifice with 5/32” Allen wrench. (Fig. 57)
3.Install the conversion orifice.
4.Reinstall pilot hood. Be sure to align hood with index tab.
Valve Conversion
Pilot Hood
Pilot
Bracket
CO133
Fig. 56 Remove pilot hood.
20011957 | 39 |