Hearth

A hearth is not mandatory but is recommended for aesthetic purposes. We recommend a noncombustible hearth which projects out 12” (305 mm) or more from the front of the fireplace. The hearth cannot exceed 1¹⁄₂” (38 mm) in height from bottom of fireplace for ease of door accessibility. (Fig. 4)

Cold climate installation recommendation: When installing this unit against a non- insulated exterior wall or chase, it is

Chateau™ Direct Vent Gas Fireplace

mandatory the outer walls be insulated to conform to applicable insulation codes.

Framing and Finishing

1.

Choose the unit location.

2.

The unit is shipped with four (4) nailing flanges

 

mounted near the front corners on the side with the

 

valve box assembly . (Fig. 4)

6" (152 mm)

1" (25 mm)

This side of fireplace must be facing interior of home

FP1467b

3.

Frame the fireplace with a header across the top of

 

the standoff. (Fig. 5) It is very important to allow for

 

the finished wall face along with marble, tiles or any

 

other noncombustible face finish material desired

 

when setting the depth of the framing.

4.

Attach the fireplace nailing flanges to the frame as

 

shown in Figure 4.

Fig. 5 Fireplace framing.

are positioned 1” (25mm) back from the face of the unit. NOTE: The U-channel depth can be adjusted by loosening the hex nut inside the channel.

If marble, tile or any other noncombustible decora- tive face finish material is desired, a 3” (76mm) wide noncombustible board (recommended Dura-Rock) is to be nailed to the nailing flanges on both sides of the unit. Also, 12” (305mm) of noncombustible board is to be nailed to the front face of the U-chan- nel and the top framing member above the standoff.

Bend

Line

6"

(152 mm) Min.

1���"

(38mm)

Max. Hearth Height

1" (25 mm) Min.

FP1357c

Combustible material can then be brought to the outside edges of the noncombustible board installed earlier. Any noncombustible decorative face finish could be brought to the sides and top of the unit and can cover the framing and sheet rock. If a decora- tive facing is not desired, then the noncombustible boards must be double thickness and brought flush with the face of the unit.

Final Finishing

Noncombustible materials such as brick or tile may be brought to the edges of the face of the appliance.

Fig. 4 Nailing flanges.

5.The gas components are located in the valve box as- sembly attached to the side of the unit.

6.The U-channel located on the top of the unit as well as the nailing flanges on the sides that were men- tioned in Step 1, are designed to accommodate non- combustible board (recommended Dura-Rock). They

20011957

7

Page 7
Image 7
Vermont Casting DTV38s2 installation instructions Hearth, Framing and Finishing, Final Finishing