Chateau™ Direct Vent Gas Fireplace

American Flame Gas Control System Error Codes

Ignition Safety: Protection for Ignition System

Error Code: One beep every one second

Description of Fault: Warn users if the pilot is not successfully ignited in 60 seconds.

How to Clear: Press OFF then ON buttons to re-attempt ignition.

What to Check:

Ensure gas supply is turned on.

Ensure orange/white leads from module are plugged into the “PILOT” connection on the valve body.

Verify the lead from igniter on pilot assembly is connected to the “I” terminal on the module.

Verify lead from flame sensor on pilot assembly is connected to the “S” terminal on the module.

Verify that the black ground lead form the module is connected to a proper ground on the fireplace.

Ensure there is no blockage in the pilot line.

Sensor Safety: Protection for Flame Sensor

Error Code: 4 beeps every one second

Description of Fault: Warn users the pilot flame sensor detects a pilot flame already present when ignition sequence is initiated. This fault will also occur if pilot flame sensor is shorted to ground.

How to Clear: Press OFF then ON buttons to re-attempt normal ignition.

What to Check:

Check if pilot flame is actually present when valve is turned OFF (valve replacement necessary if yes).

Replace pilot assembly.

Replace module.

Thermal Safety: Overheat Protection

Error Code: 4 beeps every two seconds.

Description of Fault: Warn users that the module’s internal temperature has exceeded 170° F (77° C).

How to Clear: Module’s internal temperature must cool to below 160° F (71° C) and then press ON button.

What to Check:

Is module located in unapproved location, too close to burner?

Move to cooler location.

Communication Safety: (NOTE: This feature is only available when transmitter includes an LCD screen).

Error Code: One beep every four seconds.

Description of Fault: Warn users that the transmitter and receiver are not communicating properly.

What to Check:

Verify batteries in both transmitter and receiver are new.

Ensure transmitter is located within 20 feet (6 m) of receiver.

Ensure transmitter is not placed in metal enclosure or laying directly on top of a metal surface as this can interfere with transmission.

38

20011957

Page 38
Image 38
Vermont Casting DTV38s2 installation instructions American Flame Gas Control System Error Codes, What to Check