LIGHTING AND OPERATING INSTRUCTIONS

LIGHTING AND OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This fireplace has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly.

B.BEFORE LIGHTING smell all around the fireplace area for gas. Be sure to smell next to the floor be- cause some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any fireplace.

Do not touch any electric switch

Do not use any phone in your building

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the Fire Department

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.

D.Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this label.

2.Turn off all electrical power to the fireplace.

3.For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to off position or set thermostat to lowest level.

4.Open control access panel.

5.Push in gas control knob slightly and turn clockwise

to FOR YOUR SAFETY READ BEFORE LIGHTING "OFF". Do not force.

 

 

 

ILO

OFF

 

 

 

P

T

PILOT

 

 

 

 

 

HI

F

 

 

ON

 

OFF

 

ON

 

F

 

LO

PILOT

O

 

FFO

 

 

 

 

 

 

 

 

 

 

EURO SIT

 

SIT NOVA
HONEYWELL

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to the next step.

7.Remove window frame assembly before lighting pilot. (See Window Frame Assembly Removal in manual).

8.Visibly locate pilot by the main burner.

9.Turn knob on gas control counterclockwise

to "PILOT".

10.Push the control knob all the way in and hold. Immediately light the pilot by repeatedly de- pressing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Re- lease knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

3/8" - 1/2" LIGHTING INSTRUCTIONSEURO SITSIT NOVA

•If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

•If after several tries, the pilot will not stay lit, turn the gas control knob to "OFF" and call your service technician or gas supplier.

11.Replace window frame assembly.

12.Turn gas control knob to "On" HONEYWELL position.

13.For Rn/RP appliances turn the On/Off switch to "On" positin or set thermostat to desired setting.

14.Turn on all electrical power to the fireplace.

TO TURN OFF GAS TO FIREPLACE

1.

Turn the On/Off switch to Off position or set

4.

Push in gas control knob slightly and

 

the thermostat to lowest setting.

 

turn clockwise

to "OFF". Do

2.

Turn off all electric power to the fireplace if

 

not force.

 

 

service is to be performed.

5.

Close control access panel.

3.Open control access panel.

10003929