Vermont Casting LHER20 manual Gas Specifications, Gas Inlet & Manifold Pressures, High Elevations

Models: LHER20

1 28
Download 28 pages 3.59 Kb
Page 6
Image 6
Gas Specifications

LHE Series Natural Vent Insert

Gas Specifications

 

 

 

Max.

Min.

Air Shutter

 

 

Gas

Input

Input

Setting

Model

Fuel

Control

Btu/h

Btu/h

Front

Rear

LHEC20RN

Nat. Gas

Millivolt

20,000

14,000

Fully

Closed

 

 

Hi/Lo

 

 

Open

50%

LHEC20RP

Prop. Gas

Millivolt

20,000

15,000

Fully

Fully

 

 

Hi/Lo

 

 

Open

Open

LHEC20RFN

Nat. Gas

Comfort

20,000

14,000

Fully

Closed

 

 

Control

 

 

Open

50%

LHEC20RFP

Prop. Gas

Comfort

20,000

15,000

Fully

Fully

 

 

Control

 

 

Open

Open

LHER20RN

Nat. Gas

Millivolt

20,000

14,000

Fully

Closed

 

 

Hi/Lo

 

 

Open

50%

LHER20RP

Prop. Gas

Millivolt

20,000

15,000

Fully

Closed

 

 

Hi/Lo

 

 

Open

50%

LHEC30RN

Nat. Gas

Millivolt

30,000

21,000

Fully

Closed

 

 

Hi/Lo

 

 

Open

15%

LHEC30RP

Prop. Gas

Millivolt

30,000

22,500

Fully

Closed

 

 

Hi/Lo

 

 

Open

15%

LHEC30RFN

Nat. Gas

Comfort

30,000

21,000

Fully

Closed

 

 

Control

 

 

Open

15%

LHEC30RFP

Prop. Gas

Comfort

30,000

22,500

Fully

Closed

 

 

Control

 

 

Open

15%

LHER30RN

Nat. Gas

Millivolt

30,000

21,000

Fully

Closed

 

 

Hi/Lo

 

 

Open

15%

LHER30RP

Prop. Gas

Millivolt

30,000

22,500

Fully

Closed

 

 

Hi/Lo

 

 

Open

15%

Units:

LHEC20RN GICN4B0 LHEC30RN GINN3H0 LHEC20RP GICL4B0 LHEC30RP GINL3H0

LHEC20RFN J34KC0 LHEC30RFN K32KC0 LHER20RN GIRN3B0 LHEC30RFP K32LC0 LHER20RP GIDN3B0 LHER30RN K31A30

Gas Inlet & Manifold Pressures

 

Natural

LP

Minimum Inlet Pressure

5.5" W.C.

11.0" W.C.

Maximum Inlet Pressure

14.0" W.C.

14.0" W.C.

Manifold Pressure

3.5" W.C.

10.0" W.C.

Do not use this appliance if any part of it has been under water. Immediately call a qualified service technician to inspect the unit and replace any part of the control which has been under water.

High Elevations

Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370m) above sea level.

For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.

In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370m).

These gas inserts are approved for installation in solid fuel burning masonry or zero clearance fireplaces.

LHEC20 / LHER20 / LHEC30 / LHER30

Certified To

ANSI Z 21.88-2005 / CSA 2.33-2005

Vented Gas Fireplace Heaters

Preparation

Before beginning, remove glass door and logs from unit. Also check to make sure there is no hidden damage to the unit. Take a minute and plan out the gas,venting and electrical route. It is best to start with the gas line first followed by the chimney liner. (Refer to Page 9)

Gas Line Installation

When purging the gas line, the front glass must be removed.

If gas piping from the source to the heater location has not been accomplished, install the required pipe. Consult local plumbing code to assure proper pipe size.

The gas pipeline can be brought in through the rear or the base of the heater.

NOTE: The gas line connection can be made of either properly tinned 3/8" copper tubing, 1/2" rigid pipe or an approved flex connector then reduced to 3/8" to the heater. Some municipalities have additional local codes, it is always best to consult your local authority and the CSA- B149.1 installation code.

U.S. Installations consult the current National Fuel Gas Code, ANSI Z223.1/NFPA 54.

Always check for gas leaks with a mild soap and water solution. Do not use an open flame for leak testing.

The gas control is equipped with a captured screw type pressure test point, therefore it is not necessary to provide a 1/8" test point up stream of the control.

When using copper or flex connector, use only approved fittings. Always provide a union when using black iron pipe so the gas line can be easily disconnected for burner or fan servicing. See gas specifications for pressure details and ratings. NOTE: If flex connector is used, it must be kept inside of the heater.

6

10005360