Troubleshooting

NVC Series B-Vent

Troubleshooting

Honeywell Electronic Ignition

START

 

Turn gas supply off

NO

 

Turn ON/OFF Switch

 

 

to call for heat.

 

 

 

 

 

 

 

Power to module

 

 

(24V nominal)

 

 

 

 

 

 

 

YES

 

 

NO

 

 

 

 

 

 

 

Spark across

 

Ignitor Sensor gap

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

Turn gas on

NO

Pilot burner lights?

 

 

 

YES

Spark stops when pilot

NO

is lit?

YES

CHECK : Honeywell Electronic Ignition Line Voltage (120VAC)

START Low Voltage Transformer (19.5 minimum VAC)

Manual background ON/OFF Switch

Manual background Wiring connections Manual background Thermodisk

Unplug Ignition Lead

NO

 

 

and check spark

 

Replace Module

 

 

at module

 

 

 

(24VAC nominal)

 

 

 

 

 

 

 

Spark OK?

YES

Manual background Check ignition cable, ground wiring, Ceramic Insulator and gap. Correct as necessary Manual background Check boot of ignition cable for signs of melting or buckling. Take protective actions to shield cable and boot from excessive temperatures.

Manual background Check that all manual gas valves are open, supply tubing and pressures are good, and pilot burner orifice is not blocked.

Manual background Check electrical connections between module and pilot operator on gas control. Manual background Check for 24VAC across PV-MV/PV terminals on module. If voltage is okay, replace gas control. If not, replace module.

NOTE: If S8600B goes into lockout, reset system.

Manual background Check continuity of ignition cable and ground wire.

Manual background Clean flame rod.

Manual background Check electrical connections beween flame rod and module.

Manual background Check for cracked ceramic flame rod insulator.

Manual background Check that pilot flame covers flame rod and is steady blue.

Manual background Adjust pilot flame.

Manual background If problem persists, replace module.

Main Burner lights?

YES

System runs until

ON/OFF switch is in

"OFF" position

YES Manual background

Troubleshooting

Ends

NO

NO

Manual background Check for 24VAC across MV-MV/PV terminals. If no voltage, replace module. Manual background Check electrical connections between module and gas control. If okay, replace gas control or gas control operator.

NOTE: If S8600B goes into lockout, reset system.

Manual background Check for continuity of igniton cable and ground wire. NOTE: If ground is poor or erratic, shutdowns may occur occasionally even though operation is normal

at time of checkout.

Manual background Check that the pilot flame covers flame rod and is steady and blue. Manual background If checks are okay, replace module.