Vermont Casting NVC43 Honeywell VS8421, Remove glass door before service work, Troubleshooting

Models: NVC39 NVC36 NVC43

1 28
Download 28 pages 55.09 Kb
Page 16
Image 16
Honeywell VS8421

NVC Series B-Vent

Troubleshooting

Honeywell VS8421

Remove glass door before service work

START

Gas Supply On

YES

Pilot Lights With Piezo Ignitor

YES

Pilot Stays Lit

YES

Pilot Lights Main Burner

YES

 

 

 

CHECK

 

 

 

 

 

 

 

 

NO

 

Supply Line Hooked Up

 

 

 

 

Shutoff Valve Open

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lockout Has Engaged. Wait 60

 

 

 

 

 

 

Seconds And Try Again.

 

 

 

 

 

For Spark At Electrode While

 

 

NO

 

 

 

Depressing Piezo

 

 

 

 

 

1/8" Gap To Pilot Hood Needed.

 

 

 

 

 

 

 

 

 

 

 

All Wiring Connections

 

 

 

 

 

Replace Piezo Ignitor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For Air In The Lines

 

 

 

 

 

Thermopile Needs A Min.

 

 

 

 

 

 

325mv. Adjust Pilot Flame

 

 

 

 

 

 

Height.

 

 

NO

 

 

All Wiring Connections

 

 

 

 

Replace Thermopile

 

 

 

 

 

 

 

 

 

 

Thermocouple Needs A Min. Of

 

 

 

 

 

 

14mv

 

 

 

 

 

Defective Valve. Turn To Pilot,

 

 

 

 

 

 

Meter Should Read Greater

 

 

 

 

 

 

Than 100mv. If Not, Replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Valve Is Turned On

 

 

 

 

 

Wall Switch Is Not Turned On.

 

 

NO

 

 

 

Watch For Grounded Wires!

 

 

 

 

Thermopile Needs A Min. 325mv.

 

 

 

 

 

 

 

 

 

 

Plugged Burner Orifice

 

 

 

 

 

 

 

 

System Ok